10×10×8 room to 1,200 ppm with a 20 lb CO₂ cylinder
For a sealed-volume comparison, enter a 10×10×8 ft room, a 400 ppm starting point and a 1,200 ppm planning target. The modeled regulator rate is 5 CFH.
Inputs
Results
Cylinder runtime at full flow
Ideal-gas estimate near 20 °C and 1 atm
- Room volume
- 800 ft³
- Ideal no-exchange fill gas
- 18.123 L
- Initial fill time at supply flow
- 7.68 min
- Average flow to offset air exchange
- 0 CFH
- Average holding duty
- 0 %
- Equivalent on-time per cycle
- 0 min
- Ideal fills per cylinder
- 273
- Estimated cylinder life with daily refill
- 273.54 days
Ideal fill profile
The curve assumes well-mixed air and constant exchange.
Inputs used
- Room length
- 10 ft
- Room width
- 10 ft
- Room height
- 8 ft
- Starting and incoming CO₂
- 400 ppm
- Planning target
- 1,200 ppm
- Outdoor air exchange rate
- 0 ACH
- Regulated supply flow
- 5 CFH
- Cylinder gas capacity
- 20 lb
- Nominal cycle length
- 15 min
- Daily enrichment window
- 12 h/day
Worked calculation
- Convert the ppm increase to an ideal fill volume
22,653.48 L × 800 ÷ 1,000,000 = 18.1228 L
- Calculate the air-exchange replacement flow
18.1228 L × 0 ACH ÷ 60 = 0 L/min
- Estimate the time to reach target from baseline
18.1228 L ÷ 2.3597 L/min = 7.68 min
- Estimate cylinder gas volume and full-flow runtime
20 lb = 9.0718 kg. Gas volume = 4,957.3 L. Divide by supply L/min and 60 = 35.01 h.
What the example shows
The no-exchange model needs about 18.12 L to raise concentration through 800 ppm, taking 7.68 minutes at the entered flow. The cylinder’s full-flow runtime is about 35 hours. Ventilation and monitoring remain essential in a real installation.
How the model works
The room is modeled as well mixed, with constant incoming concentration and air exchange. Gas density is 1.83 g/L near 20 °C and 1 atm. Plant uptake, poor mixing, active ventilation changes and regulator behavior alter the result.
Equivalent timer on-time describes a cycle average. Peaks and troughs depend on cycle length, mixing, sensor placement and control response. Use a monitored controller supported by ventilation and independent safety alarms.
References
Common questions
Does 35 hours mean a 20 lb tank lasts only a day and a half?
That counts time at the entered full flow. Calendar life depends on hours of injection, plant uptake, leaks and ventilation.
Why use the 800 ft³ room volume even when the plants occupy some space?
Gross dimensions provide a simple comparison. Use a measured free-air volume if large solid equipment materially changes it, and assess air mixing in an installed system.