10×10×8 room to 1,200 ppm with a 20 lb CO₂ cylinder

For a sealed-volume comparison, enter a 10×10×8 ft room, a 400 ppm starting point and a 1,200 ppm planning target. The modeled regulator rate is 5 CFH.

Inputs

Growing space and concentration
ft
ft
ft
ppm
ppm
ACH

Zero is the ideal sealed-room calculation only.

Supply and operating schedule
CFH
lb

Enter the gas mass, such as 20 lb or 50 lb.

min
h/day

Results

Cylinder runtime at full flow

35.01 hours

Ideal-gas estimate near 20 °C and 1 atm

Room volume
800 ft³
Ideal no-exchange fill gas
18.123 L
Initial fill time at supply flow
7.68 min
Average flow to offset air exchange
0 CFH
Average holding duty
0 %
Equivalent on-time per cycle
0 min
Ideal fills per cylinder
273
Estimated cylinder life with daily refill
273.54 days

Ideal fill profile

The curve assumes well-mixed air and constant exchange.

Modeled CO₂ concentration rampIdeal well-mixed fill profile. The dashed line represents the planning target.CO₂ · ppm1200400010 min

Worked calculation

  1. Convert the ppm increase to an ideal fill volume

    22,653.48 L × 800 ÷ 1,000,000 = 18.1228 L

  2. Calculate the air-exchange replacement flow

    18.1228 L × 0 ACH ÷ 60 = 0 L/min

  3. Estimate the time to reach target from baseline

    18.1228 L ÷ 2.3597 L/min = 7.68 min

  4. Estimate cylinder gas volume and full-flow runtime

    20 lb = 9.0718 kg. Gas volume = 4,957.3 L. Divide by supply L/min and 60 = 35.01 h.

What the example shows

The no-exchange model needs about 18.12 L to raise concentration through 800 ppm, taking 7.68 minutes at the entered flow. The cylinder’s full-flow runtime is about 35 hours. Ventilation and monitoring remain essential in a real installation.

How the model works

The room is modeled as well mixed, with constant incoming concentration and air exchange. Gas density is 1.83 g/L near 20 °C and 1 atm. Plant uptake, poor mixing, active ventilation changes and regulator behavior alter the result.

Equivalent timer on-time describes a cycle average. Peaks and troughs depend on cycle length, mixing, sensor placement and control response. Use a monitored controller supported by ventilation and independent safety alarms.

References

Common questions

Does 35 hours mean a 20 lb tank lasts only a day and a half?

That counts time at the entered full flow. Calendar life depends on hours of injection, plant uptake, leaks and ventilation.

Why use the 800 ft³ room volume even when the plants occupy some space?

Gross dimensions provide a simple comparison. Use a measured free-air volume if large solid equipment materially changes it, and assess air mixing in an installed system.