CO₂ fill time for a 21.6 m³ greenhouse at 1,000 ppm
A 3×3×2.4 m space starts at 420 ppm and evaluates a 1,000 ppm target with 0.6 air changes per hour. The supply setting is 2 L/min.
Inputs
Results
Cylinder runtime at full flow
Ideal-gas estimate near 20 °C and 1 atm
- Room volume
- 21.6 m³
- Ideal no-exchange fill gas
- 12.528 L
- Initial fill time at supply flow
- 6.47 min
- Average flow to offset air exchange
- 0.125 L/min
- Average holding duty
- 6.26 %
- Equivalent on-time per cycle
- 0.75 min
- Ideal fills per cylinder
- 395
- Estimated cylinder life with daily refill
- 56.79 days
Ideal fill profile
The curve assumes well-mixed air and constant exchange.
Inputs used
- Room length
- 3 m
- Room width
- 3 m
- Room height
- 2.4 m
- Starting and incoming CO₂
- 420 ppm
- Planning target
- 1,000 ppm
- Outdoor air exchange rate
- 0.6 ACH
- Regulated supply flow
- 2 L/min
- Cylinder gas capacity
- 9.07185 kg
- Nominal cycle length
- 12 min
- Daily enrichment window
- 10 h/day
Worked calculation
- Convert the ppm increase to an ideal fill volume
21,600 L × 580 ÷ 1,000,000 = 12.528 L
- Calculate the air-exchange replacement flow
12.528 L × 0.6 ACH ÷ 60 = 0.1253 L/min
- Estimate the time to reach target from baseline
−ln(1 − holding flow ÷ supply flow) ÷ (ACH ÷ 60) = 6.469 min
- Estimate cylinder gas volume and full-flow runtime
9.07 kg = 9.0718 kg. Gas volume = 4,957.3 L. Divide by supply L/min and 60 = 41.31 h.
What the example shows
The no-exchange fill equivalent is 12.53 L. Accounting for the stated exchange gives an ideal ramp of about 6.47 minutes. Use concentration feedback to evaluate a real installation.
How the model works
The room is modeled as well mixed, with constant incoming concentration and air exchange. Gas density is 1.83 g/L near 20 °C and 1 atm. Plant uptake, poor mixing, active ventilation changes and regulator behavior alter the result.
Equivalent timer on-time describes a cycle average. Peaks and troughs depend on cycle length, mixing, sensor placement and control response. Use a monitored controller supported by ventilation and independent safety alarms.
References
Common questions
Why is the calculated metric fill time longer than 12.53 L divided by 2 L/min?
Some of the added gas is removed with the exchanged air during the ramp. The model accounts for that loss as concentration rises.
Which cylinder weight goes in the metric capacity field?
Enter the labeled gas charge in kilograms. The container tare weight or the gross filled cylinder weight would overstate available gas.