When a CO₂ supply cannot reach the greenhouse ppm target
The 512 ft³ room has 400 ppm incoming air and exchanges air twice per hour. A 0.5 CFH supply is being evaluated against a 1,000 ppm target.
Inputs
Results
Cylinder runtime at full flow
Supply flow cannot reach the target at this air-exchange rate.
- Room volume
- 512 ft³
- Ideal no-exchange fill gas
- 8.699 L
- Initial fill time at supply flow
- —
- Average flow to offset air exchange
- 0.614 CFH
- Average holding duty
- —
- Equivalent on-time per cycle
- —
- Ideal fills per cylinder
- 569
- Estimated cylinder life with daily refill
- —
Ideal fill profile
The curve assumes well-mixed air and constant exchange.
Inputs used
- Room length
- 8 ft
- Room width
- 8 ft
- Room height
- 8 ft
- Starting and incoming CO₂
- 400 ppm
- Planning target
- 1,000 ppm
- Outdoor air exchange rate
- 2 ACH
- Regulated supply flow
- 0.5 CFH
- Cylinder gas capacity
- 20 lb
- Nominal cycle length
- 10 min
- Daily enrichment window
- 12 h/day
Worked calculation
- Convert the ppm increase to an ideal fill volume
14,498.23 L × 600 ÷ 1,000,000 = 8.6989 L
- Calculate the air-exchange replacement flow
8.6989 L × 2 ACH ÷ 60 = 0.29 L/min
- Estimate the time to reach target from baseline
Target requires a holding flow below the regulated supply flow.
- Estimate cylinder gas volume and full-flow runtime
20 lb = 9.0718 kg. Gas volume = 4,957.3 L. Divide by supply L/min and 60 = 350.13 h.
What the example shows
The target requires about 0.29 L/min to offset exchange, while supply is about 0.24 L/min. The model marks the target unreachable. Maintain required ventilation and review the design with a qualified installer.
How the model works
The room is modeled as well mixed, with constant incoming concentration and air exchange. Gas density is 1.83 g/L near 20 °C and 1 atm. Plant uptake, poor mixing, active ventilation changes and regulator behavior alter the result.
Equivalent timer on-time describes a cycle average. Peaks and troughs depend on cycle length, mixing, sensor placement and control response. Use a monitored controller supported by ventilation and independent safety alarms.
References
Common questions
Why does this case show a tank runtime but no time to target?
The cylinder inventory and metered flow still define how long gas can be delivered. Exchange losses keep that flow from reaching the selected concentration.
Will extending the nominal timer interval fix a flow below the holding requirement?
No. Even continuous supply in this steady model is below the exchange loss at the target. Keep the ventilation design and get a qualified system review.