CO₂ cylinder days for a 20×12 ft greenhouse
A 20×12×9 ft envelope has one modeled outdoor air change per hour. Use 420 ppm incoming air, a 950 ppm target and a 10-hour daily window.
Inputs
Results
Cylinder runtime at full flow
Ideal-gas estimate near 20 °C and 1 atm
- Room volume
- 2,160 ft³
- Ideal no-exchange fill gas
- 32.417 L
- Initial fill time at supply flow
- 7.29 min
- Average flow to offset air exchange
- 1.145 CFH
- Average holding duty
- 11.45 %
- Equivalent on-time per cycle
- 1.72 min
- Ideal fills per cylinder
- 382
- Estimated cylinder life with daily refill
- 34.94 days
Ideal fill profile
The curve assumes well-mixed air and constant exchange.
Inputs used
- Room length
- 20 ft
- Room width
- 12 ft
- Room height
- 9 ft
- Starting and incoming CO₂
- 420 ppm
- Planning target
- 950 ppm
- Outdoor air exchange rate
- 1 ACH
- Regulated supply flow
- 10 CFH
- Cylinder gas capacity
- 50 lb
- Nominal cycle length
- 15 min
- Daily enrichment window
- 10 h/day
Worked calculation
- Convert the ppm increase to an ideal fill volume
61,164.39 L × 530 ÷ 1,000,000 = 32.4171 L
- Calculate the air-exchange replacement flow
32.4171 L × 1 ACH ÷ 60 = 0.5403 L/min
- Estimate the time to reach target from baseline
−ln(1 − holding flow ÷ supply flow) ÷ (ACH ÷ 60) = 7.295 min
- Estimate cylinder gas volume and full-flow runtime
50 lb = 22.6796 kg. Gas volume = 12,393.2 L. Divide by supply L/min and 60 = 43.77 h.
What the example shows
The computed steady replacement is 0.54 L/min. The calendar estimate includes both the initial ramp from incoming concentration and exchange replacement during the rest of the window.
How the model works
The room is modeled as well mixed, with constant incoming concentration and air exchange. Gas density is 1.83 g/L near 20 °C and 1 atm. Plant uptake, poor mixing, active ventilation changes and regulator behavior alter the result.
Equivalent timer on-time describes a cycle average. Peaks and troughs depend on cycle length, mixing, sensor placement and control response. Use a monitored controller supported by ventilation and independent safety alarms.
References
Common questions
How does opening the greenhouse vent affect the ten-hour cylinder estimate?
A change in ventilation changes the air-exchange rate and gas loss. Use operating conditions from the intended ventilation schedule when comparing scenarios.
Does the 20×12 model count CO₂ taken up by the crop?
It includes room volume, ventilation and the schedule. Crop uptake also affects gas use and can be seen in measured gas delivery and concentration under normal operation.