50 lb CO₂ cylinder and duty cycle in a 12×12 room

A growing room measures 12×12×8 ft, with 400 ppm incoming air and a 1,100 ppm planning target. For comparison, enter 0.5 ACH and an 8 CFH supply.

Inputs

Growing space and concentration
ft
ft
ft
ppm
ppm
ACH

Zero is the ideal sealed-room calculation only.

Supply and operating schedule
CFH
lb

Enter the gas mass, such as 20 lb or 50 lb.

min
h/day

Results

Cylinder runtime at full flow

54.71 hours

Ideal-gas estimate near 20 °C and 1 atm

Room volume
1,152 ft³
Ideal no-exchange fill gas
22.835 L
Initial fill time at supply flow
6.21 min
Average flow to offset air exchange
0.403 CFH
Average holding duty
5.04 %
Equivalent on-time per cycle
0.5 min
Ideal fills per cylinder
542
Estimated cylinder life with daily refill
77.82 days

Ideal fill profile

The curve assumes well-mixed air and constant exchange.

Modeled CO₂ concentration rampIdeal well-mixed fill profile. The dashed line represents the planning target.CO₂ · ppm1100400010 min

Worked calculation

  1. Convert the ppm increase to an ideal fill volume

    32,621.01 L × 700 ÷ 1,000,000 = 22.8347 L

  2. Calculate the air-exchange replacement flow

    22.8347 L × 0.5 ACH ÷ 60 = 0.1903 L/min

  3. Estimate the time to reach target from baseline

    −ln(1 − holding flow ÷ supply flow) ÷ (ACH ÷ 60) = 6.206 min

  4. Estimate cylinder gas volume and full-flow runtime

    50 lb = 22.6796 kg. Gas volume = 12,393.2 L. Divide by supply L/min and 60 = 54.71 h.

What the example shows

The average exchange replacement is about 0.19 L/min. The 50 lb cylinder provides roughly 54.7 hours of full-flow inventory at the stated regulator setting.

How the model works

The room is modeled as well mixed, with constant incoming concentration and air exchange. Gas density is 1.83 g/L near 20 °C and 1 atm. Plant uptake, poor mixing, active ventilation changes and regulator behavior alter the result.

Equivalent timer on-time describes a cycle average. Peaks and troughs depend on cycle length, mixing, sensor placement and control response. Use a monitored controller supported by ventilation and independent safety alarms.

References

Common questions

Can I double the 20 lb runtime to estimate a 50 lb cylinder?

At the same gas density and flow, multiply by 50 ÷ 20 = 2.5. A gas cylinder’s usable delivery also depends on its condition and supply equipment.

What does the nominal 10-minute cycle tell me about peaks?

It gives an equivalent average on-time for the modeled loss. Peaks require concentration measurements and an appropriate sensor-based controller.