50 lb CO₂ cylinder and duty cycle in a 12×12 room
A growing room measures 12×12×8 ft, with 400 ppm incoming air and a 1,100 ppm planning target. For comparison, enter 0.5 ACH and an 8 CFH supply.
Inputs
Results
Cylinder runtime at full flow
Ideal-gas estimate near 20 °C and 1 atm
- Room volume
- 1,152 ft³
- Ideal no-exchange fill gas
- 22.835 L
- Initial fill time at supply flow
- 6.21 min
- Average flow to offset air exchange
- 0.403 CFH
- Average holding duty
- 5.04 %
- Equivalent on-time per cycle
- 0.5 min
- Ideal fills per cylinder
- 542
- Estimated cylinder life with daily refill
- 77.82 days
Ideal fill profile
The curve assumes well-mixed air and constant exchange.
Inputs used
- Room length
- 12 ft
- Room width
- 12 ft
- Room height
- 8 ft
- Starting and incoming CO₂
- 400 ppm
- Planning target
- 1,100 ppm
- Outdoor air exchange rate
- 0.5 ACH
- Regulated supply flow
- 8 CFH
- Cylinder gas capacity
- 50 lb
- Nominal cycle length
- 10 min
- Daily enrichment window
- 12 h/day
Worked calculation
- Convert the ppm increase to an ideal fill volume
32,621.01 L × 700 ÷ 1,000,000 = 22.8347 L
- Calculate the air-exchange replacement flow
22.8347 L × 0.5 ACH ÷ 60 = 0.1903 L/min
- Estimate the time to reach target from baseline
−ln(1 − holding flow ÷ supply flow) ÷ (ACH ÷ 60) = 6.206 min
- Estimate cylinder gas volume and full-flow runtime
50 lb = 22.6796 kg. Gas volume = 12,393.2 L. Divide by supply L/min and 60 = 54.71 h.
What the example shows
The average exchange replacement is about 0.19 L/min. The 50 lb cylinder provides roughly 54.7 hours of full-flow inventory at the stated regulator setting.
How the model works
The room is modeled as well mixed, with constant incoming concentration and air exchange. Gas density is 1.83 g/L near 20 °C and 1 atm. Plant uptake, poor mixing, active ventilation changes and regulator behavior alter the result.
Equivalent timer on-time describes a cycle average. Peaks and troughs depend on cycle length, mixing, sensor placement and control response. Use a monitored controller supported by ventilation and independent safety alarms.
References
Common questions
Can I double the 20 lb runtime to estimate a 50 lb cylinder?
At the same gas density and flow, multiply by 50 ÷ 20 = 2.5. A gas cylinder’s usable delivery also depends on its condition and supply equipment.
What does the nominal 10-minute cycle tell me about peaks?
It gives an equivalent average on-time for the modeled loss. Peaks require concentration measurements and an appropriate sensor-based controller.