Fixed–free coil surge
A 2.2 mm wire spring has one fixed seat and a free end in the axial vibration idealization.
Anatomy
Axial compression between supports
Screening margins
Exceeds screen-
Working shear89.95 MPa / 650 MPa
Within screen -
Shear at solid921.9 MPa / 650 MPa
Exceeds screen -
Buckling travel4 mm / 4.134 mm
Near limit -
Travel to solid4 mm / 41 mm
Within screen
Calculated values
| Axial spring rate k | 4.2318 N/mm |
|---|---|
| Working force F | 16.927 N |
| Working shear stress τ | 89.946 MPa |
| First axial surge frequency | 136.24 Hz |
| Spring index C | 8.6364 |
| Wahl factor K_w | 1.1694 |
| Total coils Nₜ | 10 |
| Solid height Lₛ | 22 mm |
| Working length L₀ − y | 59 mm |
| Travel to solid | 41 mm |
| Working clearance to solid | 37 mm |
| Force at solid height | 173.5 N |
| Estimated stress at solid | 921.94 MPa |
| Free slenderness L₀/D | 3.3158 |
| Absolute stability L₀/D limit | 1.2993 |
| Critical buckling travel | 4.134 mm |
Starting result
Keep the active mass unchanged and compare the first surge mode after changing the restraint.
- First axial surge frequency
- 136.24 Hz
- Critical buckling travel
- 4.134 mm
- Working shear stress τ
- 89.946 MPa
Model and assumptions
k = Gd⁴/(8D³Nₐ) · τ = K_w·8FD/(πd³) · f₁ = ½√(k/mₐ) for seated ends
Round wire and a linear rate up to solid. Buckling uses Wahl–Haringx lateral stability with the selected end restraint. Fixed–fixed assumes restrained seats. Surge uses active wire mass, with the fixed–free frequency halved.
References and calculation method