ASME V Article 7 · ASTM E1444/E709

High-fill coil at L/D = 5

A 50.8 mm effective diameter shaft with 254 mm length is set in a five-turn high-fill coil.

Reading the result. The nominal formula gives 5,000 A·turn or 1,000 A. A recorded field of 2.5 kA/m is above the typical comparison.

Setup

Magnetization geometry

mm
For coils use the procedure’s effective diameter.
mm

Current and field

A
kA/m
Optional. Overrides the circular estimate.
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Min. current
900A
Max. current
1100A
Center target
1000A
Surface field
2.5kA/m
Current within screening band

Verify field direction and strength on the part with the documented technique.

Magnetization and current windowFlux and equipment are shown schematically. The meter locates selected current relative to the modeled window.Field patternLongitudinal coilSelected current1000 APartField linesCurrent
Flux and equipment are shown schematically. The meter locates selected current relative to the modeled window.
Nominal coil ampere-turns
5000A·turn
Measured geometry L/D
5×
L/D used in coil formula
5×
Field reading basis
Measured input
Straight-current estimate
—
Typical field comparison
2.3873kA/m
Tangential field check
At or above 30 Oe

Use the written procedure for the part, equipment and governing edition. Field adequacy is demonstrated on the part. The circular-field estimate uses a straight current at the OD radius. Equations and references