ASME V Article 7 · ASTM E1444/E709
High-fill coil at L/D = 5
A 50.8 mm effective diameter shaft with 254 mm length is set in a five-turn high-fill coil.
Reading the result. The nominal formula gives 5,000 A·turn or 1,000 A. A recorded field of 2.5 kA/m is above the typical comparison.
Setup
Magnetization geometry
mm
For coils use the procedure’s effective diameter.
mm
mm
mm
Current and field
A
kA/m
Optional. Overrides the circular estimate.
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Min. current
- 900A
- Max. current
- 1100A
- Center target
- 1000A
- Surface field
- 2.5kA/m
Current within screening band
Verify field direction and strength on the part with the documented technique.
- Nominal coil ampere-turns
- 5000A·turn
- Measured geometry L/D
- 5×
- L/D used in coil formula
- 5×
- Field reading basis
- Measured input
- Straight-current estimate
- —
- Typical field comparison
- 2.3873kA/m
- Tangential field check
- At or above 30 Oe
Use the written procedure for the part, equipment and governing edition. Field adequacy is demonstrated on the part. The circular-field estimate uses a straight current at the OD radius. Equations and references