Short part below the coil formula range

The part is 75 mm long with an effective diameter of 50 mm, giving L/D = 1.5.

Reading the result. The coil worksheet withholds the current band below L/D = 2. A qualified technique is needed for the short geometry.

Setup

Magnetization geometry

mm
For coils use the procedure’s effective diameter.
mm

Current and field

A
kA/m
Optional. Overrides the circular estimate.
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Min. current
—
Max. current
—
Center target
—
Surface field
—
L/D below 2

The encircling-coil formulas are unavailable. Review part geometry and a qualified method.

Magnetization and current windowFlux and equipment are shown schematically. The meter locates selected current relative to the modeled window.Field patternLongitudinal coilSelected current1500 APartField linesCurrent
Flux and equipment are shown schematically. The meter locates selected current relative to the modeled window.
Nominal coil ampere-turns
—
Measured geometry L/D
1.5×
L/D used in coil formula
—
Field reading basis
Measurement needed
Straight-current estimate
—
Typical field comparison
2.3873kA/m
Tangential field check
Measure on part

Use the written procedure for the part, equipment and governing edition. Field adequacy is demonstrated on the part. The circular-field estimate uses a straight current at the OD radius. Equations and references