ASME V Article 7 · ASTM E1444/E709

2 in shaft direct head shot

A 2 in ferromagnetic shaft is screened at 1,100 A for direct circular magnetization.

Reading the result. The diameter guideline spans 600–1,600 A. Its midpoint is 1,100 A and the field check remains separate.

Setup

Magnetization geometry

mm
For coils use the procedure’s effective diameter.

Current and field

A
kA/m
Optional. Overrides the circular estimate.
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Min. current
600A
Max. current
1600A
Center target
1100A
Surface field
6.8925kA/m
Current within screening band

Verify field direction and strength on the part with the documented technique.

Magnetization and current windowFlux and equipment are shown schematically. The meter locates selected current relative to the modeled window.Field patternDirect head shotSelected current1100 APartField linesCurrent
Flux and equipment are shown schematically. The meter locates selected current relative to the modeled window.
Nominal coil ampere-turns
—
Measured geometry L/D
—
L/D used in coil formula
—
Field reading basis
Straight-current estimate
Straight-current estimate
6.8925kA/m
Typical field comparison
2.3873kA/m
Tangential field check
At or above 30 Oe

Use the written procedure for the part, equipment and governing edition. Field adequacy is demonstrated on the part. The circular-field estimate uses a straight current at the OD radius. Equations and references