ASME V Article 7 · ASTM E1444/E709

4 in prod spacing on thin plate

Prods are placed 4 in apart on a part thinner than ¾ in. The selected current is 425 A.

Reading the result. The thin-part factors give a 360–440 A band. Use a measured field for verification of this method.

Setup

Magnetization geometry

mm
mm

Current and field

A
kA/m
Optional. Overrides the circular estimate.
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Min. current
360A
Max. current
440A
Center target
400A
Surface field
—
Current within screening band

Verify field direction and strength on the part with the documented technique.

Magnetization and current windowFlux and equipment are shown schematically. The meter locates selected current relative to the modeled window.Field patternProd contactsSelected current425 APartField linesCurrent
Flux and equipment are shown schematically. The meter locates selected current relative to the modeled window.
Nominal coil ampere-turns
—
Measured geometry L/D
—
L/D used in coil formula
—
Field reading basis
Measurement needed
Straight-current estimate
—
Typical field comparison
2.3873kA/m
Tangential field check
Measure on part

Use the written procedure for the part, equipment and governing edition. Field adequacy is demonstrated on the part. The circular-field estimate uses a straight current at the OD radius. Equations and references