ASME V Article 7 · ASTM E1444/E709
Long shaft with capped low-fill L/D
The part is placed against the wall of a low-fill coil. The geometric ratio is 20 and the coil has five effective turns.
Reading the result. Apply the screening cap at L/D = 15. The nominal 3,000 A·turn is equivalent to 600 A in five turns.
Setup
Magnetization geometry
mm
For coils use the procedure’s effective diameter.
mm
mm
mm
Current and field
A
kA/m
Optional. Overrides the circular estimate.
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Min. current
- 540A
- Max. current
- 660A
- Center target
- 600A
- Surface field
- —
Current within screening band
Verify field direction and strength on the part with the documented technique.
- Nominal coil ampere-turns
- 3000A·turn
- Measured geometry L/D
- 20×
- L/D used in coil formula
- 15×
- Field reading basis
- Measurement needed
- Straight-current estimate
- —
- Typical field comparison
- 2.3873kA/m
- Tangential field check
- Measure on part
- The calculation caps L/D at 15. Evaluate segment coverage in the qualified procedure.
Use the written procedure for the part, equipment and governing edition. Field adequacy is demonstrated on the part. The circular-field estimate uses a straight current at the OD radius. Equations and references