ASME V Article 7 · ASTM E1444/E709

Long shaft with capped low-fill L/D

The part is placed against the wall of a low-fill coil. The geometric ratio is 20 and the coil has five effective turns.

Reading the result. Apply the screening cap at L/D = 15. The nominal 3,000 A·turn is equivalent to 600 A in five turns.

Setup

Magnetization geometry

mm
For coils use the procedure’s effective diameter.
mm

Current and field

A
kA/m
Optional. Overrides the circular estimate.
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Min. current
540A
Max. current
660A
Center target
600A
Surface field
—
Current within screening band

Verify field direction and strength on the part with the documented technique.

Magnetization and current windowFlux and equipment are shown schematically. The meter locates selected current relative to the modeled window.Field patternLongitudinal coilSelected current600 APartField linesCurrent
Flux and equipment are shown schematically. The meter locates selected current relative to the modeled window.
Nominal coil ampere-turns
3000A·turn
Measured geometry L/D
20×
L/D used in coil formula
15×
Field reading basis
Measurement needed
Straight-current estimate
—
Typical field comparison
2.3873kA/m
Tangential field check
Measure on part
  • The calculation caps L/D at 15. Evaluate segment coverage in the qualified procedure.

Use the written procedure for the part, equipment and governing edition. Field adequacy is demonstrated on the part. The circular-field estimate uses a straight current at the OD radius. Equations and references