ASME V Article 7 · ASTM E1444/E709
Short part below the coil formula range
The part is 75 mm long with an effective diameter of 50 mm, giving L/D = 1.5.
Reading the result. The coil worksheet withholds the current band below L/D = 2. A qualified technique is needed for the short geometry.
Setup
Magnetization geometry
mm
For coils use the procedure’s effective diameter.
mm
mm
mm
Current and field
A
kA/m
Optional. Overrides the circular estimate.
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Min. current
- —
- Max. current
- —
- Center target
- —
- Surface field
- —
L/D below 2
The encircling-coil formulas are unavailable. Review part geometry and a qualified method.
- Nominal coil ampere-turns
- —
- Measured geometry L/D
- 1.5×
- L/D used in coil formula
- —
- Field reading basis
- Measurement needed
- Straight-current estimate
- —
- Typical field comparison
- 2.3873kA/m
- Tangential field check
- Measure on part
Use the written procedure for the part, equipment and governing edition. Field adequacy is demonstrated on the part. The circular-field estimate uses a straight current at the OD radius. Equations and references