ASME V Article 7 · ASTM E1444/E709
4 in prod spacing on thin plate
Prods are placed 4 in apart on a part thinner than ¾ in. The selected current is 425 A.
Reading the result. The thin-part factors give a 360–440 A band. Use a measured field for verification of this method.
Setup
Magnetization geometry
mm
For coils use the procedure’s effective diameter.
mm
mm
mm
Current and field
A
kA/m
Optional. Overrides the circular estimate.
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Min. current
- 360A
- Max. current
- 440A
- Center target
- 400A
- Surface field
- —
Current within screening band
Verify field direction and strength on the part with the documented technique.
- Nominal coil ampere-turns
- —
- Measured geometry L/D
- —
- L/D used in coil formula
- —
- Field reading basis
- Measurement needed
- Straight-current estimate
- —
- Typical field comparison
- 2.3873kA/m
- Tangential field check
- Measure on part
Use the written procedure for the part, equipment and governing edition. Field adequacy is demonstrated on the part. The circular-field estimate uses a straight current at the OD radius. Equations and references