ASME V Article 7 · ASTM E1444/E709
2 in shaft direct head shot
A 2 in ferromagnetic shaft is screened at 1,100 A for direct circular magnetization.
Reading the result. The diameter guideline spans 600–1,600 A. Its midpoint is 1,100 A and the field check remains separate.
Setup
Magnetization geometry
mm
For coils use the procedure’s effective diameter.
mm
mm
mm
Current and field
A
kA/m
Optional. Overrides the circular estimate.
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Min. current
- 600A
- Max. current
- 1600A
- Center target
- 1100A
- Surface field
- 6.8925kA/m
Current within screening band
Verify field direction and strength on the part with the documented technique.
- Nominal coil ampere-turns
- —
- Measured geometry L/D
- —
- L/D used in coil formula
- —
- Field reading basis
- Straight-current estimate
- Straight-current estimate
- 6.8925kA/m
- Typical field comparison
- 2.3873kA/m
- Tangential field check
- At or above 30 Oe
Use the written procedure for the part, equipment and governing edition. Field adequacy is demonstrated on the part. The circular-field estimate uses a straight current at the OD radius. Equations and references