ASME V Article 2 · Ug screen
4 in weld with short source-to-film distance
A 4 in joint is set at 240 mm SFD with a 4 mm effective gamma-source size.
Reading the result. The 0.040 in tier still applies at exactly 4 in. The close source position puts Ug above that limit.
Setup
Exposure geometry
mm
mm
Film-side surface in contact.
mm
Reference shot
mm
min
GBq
Activity at the reference shot.
GBq
d
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Calculated Ug
- 2.9364mm
- ASME Ug limit
- 1.016mm
- Minimum SFD
- 501.6mm
- Exposure time
- 0.71111min
Fail · exceeds ASME Ug screen
Increase SFD or review source size and film placement.
- Source-to-object distance
- 138.4mm
- Ug margin to limit
- -1.9204mm
- Inverse-square time factor
- 0.28444×
- Source half-life
- 1925.2d
- Decay-adjusted activity
- 1850GBq
- Remaining activity
- 100%
- Activity correction
- 1×
Use the project-specified Section V edition and its native limit table. The exposure estimate assumes the same object, detector and beam conditions as the reference. Verify the approved technique and image-quality indicators. Equations and references