ASME V Article 2 · Ug screen

Geometry at the exact 2 in thickness tier

An X-ray setup uses an effective source of 4 mm with a 2 in object at 450 mm SFD.

Reading the result. At exactly 2 in the screen moves to the 0.030 in tier. The shell and detector positioning assumptions still apply.

Setup

Exposure geometry

mm
mm
Film-side surface in contact.
mm

Reference shot

mm
min
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Calculated Ug
0.50902mm
ASME Ug limit
0.762mm
Minimum SFD
317.47mm
Exposure time
2.5min
Pass · within Ug limit

This verdict covers the geometric unsharpness screen only.

Focal spot projection onto filmObject is assumed in contact with the film or detector. The shaded band represents geometric penumbra.Radiographic setupContact geometryUg / thickness limit66.8%Source spotObjectFilm blur
Object is assumed in contact with the film or detector. The shaded band represents geometric penumbra.
Source-to-object distance
399.2mm
Ug margin to limit
0.25298mm
Inverse-square time factor
1×
Source half-life
—
Decay-adjusted activity
—
Remaining activity
—
Activity correction
1×

Use the project-specified Section V edition and its native limit table. The exposure estimate assumes the same object, detector and beam conditions as the reference. Verify the approved technique and image-quality indicators. Equations and references