ASME V Article 2 · Ug screen
X-ray tube with twice the reference SFD
A cabinet technique moves from 250 mm to 500 mm with fixed tube output, object and detector.
Reading the result. Doubling SFD multiplies the reference exposure time by four. No radioactive decay term is applied.
Setup
Exposure geometry
mm
mm
Film-side surface in contact.
mm
Reference shot
mm
min
GBq
Activity at the reference shot.
GBq
d
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Calculated Ug
- 0.016667mm
- ASME Ug limit
- 0.508mm
- Minimum SFD
- 35.748mm
- Exposure time
- 3min
Pass · within Ug limit
This verdict covers the geometric unsharpness screen only.
- Source-to-object distance
- 480mm
- Ug margin to limit
- 0.49133mm
- Inverse-square time factor
- 4×
- Source half-life
- —
- Decay-adjusted activity
- —
- Remaining activity
- —
- Activity correction
- 1×
Use the project-specified Section V edition and its native limit table. The exposure estimate assumes the same object, detector and beam conditions as the reference. Verify the approved technique and image-quality indicators. Equations and references