Point-source estimate · IAEA SSG-11

Cs-137 with two steel HVLs

The source and a 60 mm steel path illustrate the exponentially decreasing gamma component.

Reading the result. A thickness twice the 30 mm first-HVL reference models a 75% reduction. The rate target remains a comparison level.

Setup

Source and shielding

GBq
mm
×
1 = no reduction. Use a directional factor.

Distance and shift

m
min
mSv
mSv
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Bare rate
0.34299mSv/h
Shielded rate
0.021437mSv/h
Model radius
1.4641m
Shift dose
0.010716mSv
Within modeled targets

Field barricades require an approved radiation protection plan and calibrated survey measurements.

Modeled boundary and attenuationRings compare the selected work distance with the model radius. The attenuation plot uses a logarithmic transmission axis.Gamma field modelLog transmissionWork distance / model radius6.83×Model ringWork pointHVL / TVL
Rings compare the selected work distance with the model radius. The attenuation plot uses a logarithmic transmission axis.
Gamma-rate coefficient Γ
0.0927mSv·m²/h/GBq
Half-value layer
30mm
Tenth-value layer
69mm
HVL transmission
25%
TVL transmission
13.503%
Rate comparison level
1mSv/h
Dose per shot at work distance
0.00071456mSv
Shift planning check
At or below planning level

Planning model only. Field barricades require an approved radiation protection plan, qualified oversight and calibrated surveys. Scattering, leakage, buildup and beam direction can change the actual boundary. Equations and references