Point-source estimate · IAEA SSG-11

Ir-192 with two representative lead HVLs

An Ir-192 planning example combines two lead HVLs and a direction-specific collimator reduction of four.

Reading the result. The lead term transmits 25% in the selected HVL model. The displayed radius is a model comparison point for survey planning.

Setup

Source and shielding

GBq
mm
×
1 = no reduction. Use a directional factor.

Distance and shift

m
min
mSv
mSv
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Bare rate
0.26667mSv/h
Shielded rate
0.016667mSv/h
Model radius
27.386m
Shift dose
0.0094444mSv
Within modeled targets

Field barricades require an approved radiation protection plan and calibrated survey measurements.

Modeled boundary and attenuationRings compare the selected work distance with the model radius. The attenuation plot uses a logarithmic transmission axis.Gamma field modelLog transmissionWork distance / model radius1.0954×Model ringWork pointHVL / TVL
Rings compare the selected work distance with the model radius. The attenuation plot uses a logarithmic transmission axis.
Gamma-rate coefficient Γ
0.12973mSv·m²/h/GBq
Half-value layer
6mm
Tenth-value layer
16mm
HVL transmission
25%
TVL transmission
17.783%
Rate comparison level
0.02mSv/h
Dose per shot at work distance
0.00055556mSv
Shift planning check
At or below planning level

Planning model only. Field barricades require an approved radiation protection plan, qualified oversight and calibrated surveys. Scattering, leakage, buildup and beam direction can change the actual boundary. Equations and references