Point-source estimate · IAEA SSG-11

A shift dose planning level exceeded

A steel-screen planning case evaluates many shots at a work location already carrying a prior shift estimate.

Reading the result. The instantaneous comparison can pass while total modeled shift dose is above its own planning level.

Setup

Source and shielding

GBq
mm
×
1 = no reduction. Use a directional factor.

Distance and shift

m
mSv/h
min
mSv
mSv
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Bare rate
0.75mSv/h
Shielded rate
0.23338mSv/h
Model radius
7.7295m
Shift dose
0.24338mSv
Modeled shift exceeds level

The instantaneous screen is within target. The added dose exceeds the remaining shift allowance.

Modeled boundary and attenuationRings compare the selected work distance with the model radius. The attenuation plot uses a logarithmic transmission axis.Gamma field modelLog transmissionWork distance / model radius1.035×Model ringWork pointHVL / TVL
Rings compare the selected work distance with the model radius. The attenuation plot uses a logarithmic transmission axis.
Gamma-rate coefficient Γ
0.12973mSv·m²/h/GBq
Half-value layer
19mm
Tenth-value layer
49mm
HVL transmission
62.235%
TVL transmission
54.287%
Rate comparison level
0.25mSv/h
Dose per shot at work distance
0.011669mSv
Shift planning check
Exceeds planning level

Planning model only. Field barricades require an approved radiation protection plan, qualified oversight and calibrated surveys. Scattering, leakage, buildup and beam direction can change the actual boundary. Equations and references