Point-source estimate · IAEA SSG-11
A shift dose planning level exceeded
A steel-screen planning case evaluates many shots at a work location already carrying a prior shift estimate.
Reading the result. The instantaneous comparison can pass while total modeled shift dose is above its own planning level.
Setup
Source and shielding
GBq
mm
×
1 = no reduction. Use a directional factor.
Distance and shift
m
mSv/h
min
mSv
mSv
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Bare rate
- 0.75mSv/h
- Shielded rate
- 0.23338mSv/h
- Model radius
- 7.7295m
- Shift dose
- 0.24338mSv
Modeled shift exceeds level
The instantaneous screen is within target. The added dose exceeds the remaining shift allowance.
- Gamma-rate coefficient Γ
- 0.12973mSv·m²/h/GBq
- Half-value layer
- 19mm
- Tenth-value layer
- 49mm
- HVL transmission
- 62.235%
- TVL transmission
- 54.287%
- Rate comparison level
- 0.25mSv/h
- Dose per shot at work distance
- 0.011669mSv
- Shift planning check
- Exceeds planning level
Planning model only. Field barricades require an approved radiation protection plan, qualified oversight and calibrated surveys. Scattering, leakage, buildup and beam direction can change the actual boundary. Equations and references