Point-source estimate · IAEA SSG-11

Se-75 behind one tungsten HVL

A manufacturer’s representative 0.8 mm Se-75 tungsten layer is used in this attenuation comparison.

Reading the result. The model gives 50% transmission for the tungsten path. Equipment leakage and scatter require independent measurements.

Setup

Source and shielding

GBq
mm
×
1 = no reduction. Use a directional factor.

Distance and shift

m
min
mSv
mSv
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Bare rate
0.01624mSv/h
Shielded rate
0.00203mSv/h
Model radius
15.93m
Shift dose
0.0055413mSv
Within modeled targets

Field barricades require an approved radiation protection plan and calibrated survey measurements.

Modeled boundary and attenuationRings compare the selected work distance with the model radius. The attenuation plot uses a logarithmic transmission axis.Gamma field modelLog transmissionWork distance / model radius3.1388×Model ringWork pointHVL / TVL
Rings compare the selected work distance with the model radius. The attenuation plot uses a logarithmic transmission axis.
Gamma-rate coefficient Γ
0.054865mSv·m²/h/GBq
Half-value layer
0.8mm
Tenth-value layer
4mm
HVL transmission
50%
TVL transmission
63.096%
Rate comparison level
0.02mSv/h
Dose per shot at work distance
6.767e-5mSv
Shift planning check
At or below planning level
  • Dense-metal presets may represent narrow-beam attenuation. Alloy, energy and scatter change real performance.

Planning model only. Field barricades require an approved radiation protection plan, qualified oversight and calibrated surveys. Scattering, leakage, buildup and beam direction can change the actual boundary. Equations and references