Point-source estimate · IAEA SSG-11

Unshielded Ir-192 comparison

A 1 Ci point source is modeled at 1 m with zero thickness and no collimation reduction.

Reading the result. Both attenuation methods transmit 100%. The modeled unshielded rate is 4.8 mSv/h at that reference distance.

Setup

Source and shielding

GBq
mm
×
1 = no reduction. Use a directional factor.

Distance and shift

m
min
mSv
mSv
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Bare rate
4.8mSv/h
Shielded rate
4.8mSv/h
Model radius
15.492m
Shift dose
1.285mSv
Modeled rate exceeds target

The point-source model predicts a higher rate at the selected work distance.

Modeled boundary and attenuationRings compare the selected work distance with the model radius. The attenuation plot uses a logarithmic transmission axis.Gamma field modelLog transmissionWork distance / model radius0.06455×Model ringWork pointHVL / TVL
Rings compare the selected work distance with the model radius. The attenuation plot uses a logarithmic transmission axis.
Gamma-rate coefficient Γ
0.12973mSv·m²/h/GBq
Half-value layer
6mm
Tenth-value layer
16mm
HVL transmission
100%
TVL transmission
100%
Rate comparison level
0.02mSv/h
Dose per shot at work distance
0.16mSv
Shift planning check
Exceeds planning level

Planning model only. Field barricades require an approved radiation protection plan, qualified oversight and calibrated surveys. Scattering, leakage, buildup and beam direction can change the actual boundary. Equations and references