Point-source estimate · IAEA SSG-11
Unshielded Ir-192 comparison
A 1 Ci point source is modeled at 1 m with zero thickness and no collimation reduction.
Reading the result. Both attenuation methods transmit 100%. The modeled unshielded rate is 4.8 mSv/h at that reference distance.
Setup
Source and shielding
GBq
mm
×
1 = no reduction. Use a directional factor.
Distance and shift
m
mSv/h
min
mSv
mSv
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Bare rate
- 4.8mSv/h
- Shielded rate
- 4.8mSv/h
- Model radius
- 15.492m
- Shift dose
- 1.285mSv
Modeled rate exceeds target
The point-source model predicts a higher rate at the selected work distance.
- Gamma-rate coefficient Γ
- 0.12973mSv·m²/h/GBq
- Half-value layer
- 6mm
- Tenth-value layer
- 16mm
- HVL transmission
- 100%
- TVL transmission
- 100%
- Rate comparison level
- 0.02mSv/h
- Dose per shot at work distance
- 0.16mSv
- Shift planning check
- Exceeds planning level
Planning model only. Field barricades require an approved radiation protection plan, qualified oversight and calibrated surveys. Scattering, leakage, buildup and beam direction can change the actual boundary. Equations and references