Point-source estimate · IAEA SSG-11
Se-75 behind one tungsten HVL
A manufacturer’s representative 0.8 mm Se-75 tungsten layer is used in this attenuation comparison.
Reading the result. The model gives 50% transmission for the tungsten path. Equipment leakage and scatter require independent measurements.
Setup
Source and shielding
GBq
mm
×
1 = no reduction. Use a directional factor.
Distance and shift
m
mSv/h
min
mSv
mSv
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Bare rate
- 0.01624mSv/h
- Shielded rate
- 0.00203mSv/h
- Model radius
- 15.93m
- Shift dose
- 0.0055413mSv
Within modeled targets
Field barricades require an approved radiation protection plan and calibrated survey measurements.
- Gamma-rate coefficient Γ
- 0.054865mSv·m²/h/GBq
- Half-value layer
- 0.8mm
- Tenth-value layer
- 4mm
- HVL transmission
- 50%
- TVL transmission
- 63.096%
- Rate comparison level
- 0.02mSv/h
- Dose per shot at work distance
- 6.767e-5mSv
- Shift planning check
- At or below planning level
- Dense-metal presets may represent narrow-beam attenuation. Alloy, energy and scatter change real performance.
Planning model only. Field barricades require an approved radiation protection plan, qualified oversight and calibrated surveys. Scattering, leakage, buildup and beam direction can change the actual boundary. Equations and references