ASME V Article 4 · ISO 10863

Measured lateral pulse masks a shallow tip

A lateral pulse occupies 0.2 µs after arrival. The upper diffraction pick lags by 0.02 µs.

Reading the result. One sample is shorter than the pulse width, so the measured pulse controls the lateral screen.

Setup

Probe geometry

mm
mm
°
PCS target places crossing at ⅔ thickness.
m/s

Arrival time picks

µs
µs
µs
µs
0 uses one sample as a lower bound.
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Top tip depth
1.8983mm
Bot. tip depth
7.6499mm
Flaw height
5.7516mm
Lateral zone
6.0299mm
Top tip in lateral obscured zone

The top pick lies within the modeled pulse or sample window. Resolve the indication on a calibration block.

Probe pair and TOFD arrivalsThe cross-section shows the midline flaw model. The timing sketch traces lateral, tip and backwall arrivals as a scan passes the flaw.Pitch-catch setupTime tracesLateral → backwall0.3 µs apartLateralTip pathsBackwall
The cross-section shows the midline flaw model. The timing sketch traces lateral, tip and backwall arrivals as a scan passes the flaw.
PCS target at ⅔ wall
57.735mm
Lateral arrival in chosen datum
0µs
Lateral material travel time
10µs
Backwall arrival in chosen datum
3.0171µs
Backwall material travel time
13.017µs
Two-wedge delay
—
Tip-pick separation
0.3µs
Modeled obscuring interval
0.2µs
Depth change per sample at top tip
0.42722mm

Use a calibrated material velocity, actual probe index separation and measured pulse duration. Off-midline reflectors, wedges and wave overlap require a qualified TOFD setup. Equations and references