ASME V Article 4 · ISO 10863

Lateral-referenced picks on a thick wall

A 60 mm probe separation and a 6,000 m/s speed give a 10 µs lateral wave. The instrument records the two lags directly.

Reading the result. A 0.72 to 1.00 µs lag span converts into about 2.16 mm of centered flaw height.

Setup

Probe geometry

mm
mm
°
PCS target places crossing at ⅔ thickness.
m/s

Arrival time picks

µs
µs
µs
µs
0 uses one sample as a lower bound.
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Top tip depth
11.587mm
Bot. tip depth
13.748mm
Flaw height
2.1604mm
Lateral zone
4.2532mm
Tip picks clear the timing screen

Depths assume the two tips lie on the probe-pair midline.

Probe pair and TOFD arrivalsThe cross-section shows the midline flaw model. The timing sketch traces lateral, tip and backwall arrivals as a scan passes the flaw.Pitch-catch setupTime tracesLateral → backwall0.28 µs apartLateralTip pathsBackwall
The cross-section shows the midline flaw model. The timing sketch traces lateral, tip and backwall arrivals as a scan passes the flaw.
PCS target at ⅔ wall
69.282mm
Lateral arrival in chosen datum
0µs
Lateral material travel time
10µs
Backwall arrival in chosen datum
4.1421µs
Backwall material travel time
14.142µs
Two-wedge delay
—
Tip-pick separation
0.28µs
Modeled obscuring interval
0.1µs
Depth change per sample at top tip
0.1655mm

Use a calibrated material velocity, actual probe index separation and measured pulse duration. Off-midline reflectors, wedges and wave overlap require a qualified TOFD setup. Equations and references