ASME V Article 4 · ISO 10863
Tip separation below one digitized sample
Two late picks are just 0.01 µs apart while the acquisition sample interval is 0.05 µs.
Reading the result. The geometric result is about 0.072 mm. The timing screen indicates that the sample spacing is coarser than the pick separation.
Setup
Probe geometry
mm
mm
°
PCS target places crossing at ⅔ thickness.
m/s
Arrival time picks
mm
m/s
µs
µs
µs
µs
0 uses one sample as a lower bound.
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Top tip depth
- 13.748mm
- Bot. tip depth
- 13.82mm
- Flaw height
- 0.071857mm
- Lateral zone
- 3.0037mm
Tip separation below one sample
This time difference is finer than the entered digitization interval.
- PCS target at ⅔ wall
- 69.282mm
- Lateral arrival in chosen datum
- 0µs
- Lateral material travel time
- 10µs
- Backwall arrival in chosen datum
- 4.1421µs
- Backwall material travel time
- 14.142µs
- Two-wedge delay
- —
- Tip-pick separation
- 0.01µs
- Modeled obscuring interval
- 0.05µs
- Depth change per sample at top tip
- 0.35626mm
Use a calibrated material velocity, actual probe index separation and measured pulse duration. Off-midline reflectors, wedges and wave overlap require a qualified TOFD setup. Equations and references