ASME V Article 4 · ISO 10863

Tip separation below one digitized sample

Two late picks are just 0.01 µs apart while the acquisition sample interval is 0.05 µs.

Reading the result. The geometric result is about 0.072 mm. The timing screen indicates that the sample spacing is coarser than the pick separation.

Setup

Probe geometry

mm
mm
°
PCS target places crossing at ⅔ thickness.
m/s

Arrival time picks

µs
µs
µs
µs
0 uses one sample as a lower bound.
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Top tip depth
13.748mm
Bot. tip depth
13.82mm
Flaw height
0.071857mm
Lateral zone
3.0037mm
Tip separation below one sample

This time difference is finer than the entered digitization interval.

Probe pair and TOFD arrivalsThe cross-section shows the midline flaw model. The timing sketch traces lateral, tip and backwall arrivals as a scan passes the flaw.Pitch-catch setupTime tracesLateral → backwall0.01 µs apartLateralTip pathsBackwall
The cross-section shows the midline flaw model. The timing sketch traces lateral, tip and backwall arrivals as a scan passes the flaw.
PCS target at ⅔ wall
69.282mm
Lateral arrival in chosen datum
0µs
Lateral material travel time
10µs
Backwall arrival in chosen datum
4.1421µs
Backwall material travel time
14.142µs
Two-wedge delay
—
Tip-pick separation
0.01µs
Modeled obscuring interval
0.05µs
Depth change per sample at top tip
0.35626mm

Use a calibrated material velocity, actual probe index separation and measured pulse duration. Off-midline reflectors, wedges and wave overlap require a qualified TOFD setup. Equations and references