ASME V Article 4 · ISO 10863
Top pick coincident with the lateral wave
The upper signal is at exactly zero lag from the lateral wave, while the lower pick is 0.52 µs later.
Reading the result. The top calculation gives depth zero. Timing overlap flags the setup because the tip is inside the lateral obscured zone.
Setup
Probe geometry
mm
mm
°
PCS target places crossing at ⅔ thickness.
m/s
Arrival time picks
mm
m/s
µs
µs
µs
µs
0 uses one sample as a lower bound.
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Top tip depth
- 0mm
- Bot. tip depth
- 9.7997mm
- Flaw height
- 9.7997mm
- Lateral zone
- 4.2532mm
Top tip in lateral obscured zone
The top pick lies within the modeled pulse or sample window. Resolve the indication on a calibration block.
- PCS target at ⅔ wall
- 69.282mm
- Lateral arrival in chosen datum
- 0µs
- Lateral material travel time
- 10µs
- Backwall arrival in chosen datum
- 4.1421µs
- Backwall material travel time
- 14.142µs
- Two-wedge delay
- —
- Tip-pick separation
- 0.52µs
- Modeled obscuring interval
- 0.1µs
- Depth change per sample at top tip
- 1.8983mm
Use a calibrated material velocity, actual probe index separation and measured pulse duration. Off-midline reflectors, wedges and wave overlap require a qualified TOFD setup. Equations and references