Worked example

A3 reach on an adverse invert

A 1.2 m flume carries 1.4 m³/s while the invert rises 0.15% downstream. Trace shallow flow from 0.28 to 0.38 m.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Use a positive slope for falling bed, zero for level or a negative value for adverse slope.
Profile controls
m
m
m
m
Use 1 for uniform section velocity.

Hydraulic readout

A3 · Downstream profile

Reach distance: 9.50029 m, Critical depth: 0.517755 m, Min. freeboard: 0.37 m

Gradually varied water-surface profileThe direct-step stations are plotted with the channel bed, critical depth and normal depth where defined. The second chart compares depth and available freeboard.REACH DISTANCE9.5003 mNORMAL DEPTH—CRITICAL DEPTH0.51775 mMIN. FREEBOARD0.37 mWater surface · downstream →WaterNormal yₙCrit. y꜀Channel depth & freeboardDepthLimitBankAvailable freeboard0.37 m / 0.14 m
  • Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.

Calculation details

Profile type
A3
Bed slope class
Adverse
Direction
Downstream
Target station
9.50029 m
Required freeboard
0.14 m

Direct-step station schedule

StationmDepthmVelocitym/sFroudeFriction slope
00.284.16672.51450.045643
0.560590.2854.09362.44860.043354
1.11340.294.0232.38560.041221
1.65830.2953.95482.32520.03923
2.1950.33.88892.26730.037369
2.72330.3053.82512.21180.035628
3.2430.313.76342.15850.033997
3.75380.3153.70372.10730.032468
4.25560.323.64582.05810.031032
4.74820.3253.58972.01080.029683
5.23130.333.53541.96520.028413
5.70480.3353.48261.92140.027218
6.16850.343.43141.87920.026091
6.62210.3453.38161.83850.025029
7.06550.353.33331.79920.024025
7.49840.3553.28641.76130.023076
7.92070.363.24071.72480.022179
8.33230.3653.19631.68950.02133
8.73280.373.15321.65530.020525
9.12220.3753.11111.62230.019762
9.50030.383.07021.59040.019038

Interpreting this example

Both depths are below critical, which gives A3. The adverse slope and friction act together in the longitudinal energy balance.

Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)

Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.

Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet