Worked example
Chow M1 backwater behind a dam
An idealized dam backs Chow’s 400 cfs trapezoidal channel up to 5 ft. Trace the profile toward 3.4 ft using α = 1.10.
Inputs
Hydraulic readout
M1 · Upstream profile
Reach distance: 2,342.03 ft, Normal depth: 3.36107 ft, Critical depth: 2.2125 ft, Min. freeboard: 1 ft
Input values
- Discharge Q
- 400 cfs
- Bottom width b
- 20 ft
- Side slope z (H:1V)
- 2
- Bed slope S₀
- 0.0016
- Manning n
- 0.025
- Control depth y₁
- 5 ft
- Target depth y₂
- 3.4 ft
- Bank depth
- 6 ft
- Minimum freeboard
- 0.5 ft
- Velocity-head factor α
- 1.1
- Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.
Calculation details
- Profile type
- M1
- Bed slope class
- Mild
- Direction
- Upstream
- Target station
- -2,342.03 ft
- Required freeboard
- 0.5 ft
Direct-step station schedule
| Stationft | Depthft | Velocityft/s | Froude | Friction slope |
|---|---|---|---|---|
| 0 | 5 | 2.6667 | 0.24277 | 3.7295e-4 |
| -61.429 | 4.92 | 2.7246 | 0.24972 | 3.9613e-4 |
| -123.84 | 4.84 | 2.7845 | 0.25696 | 4.2111e-4 |
| -187.35 | 4.76 | 2.8467 | 0.26453 | 4.4808e-4 |
| -252.11 | 4.68 | 2.9111 | 0.27244 | 4.7722e-4 |
| -318.3 | 4.6 | 2.978 | 0.28071 | 5.0875e-4 |
| -386.12 | 4.52 | 3.0474 | 0.28937 | 5.4291e-4 |
| -455.83 | 4.44 | 3.1195 | 0.29844 | 5.7997e-4 |
| -527.75 | 4.36 | 3.1944 | 0.30794 | 6.2022e-4 |
| -602.27 | 4.28 | 3.2723 | 0.31791 | 6.6401e-4 |
| -679.91 | 4.2 | 3.3535 | 0.32838 | 7.1171e-4 |
| -761.31 | 4.12 | 3.4379 | 0.33938 | 7.6376e-4 |
| -847.37 | 4.04 | 3.526 | 0.35096 | 8.2064e-4 |
| -939.3 | 3.96 | 3.6178 | 0.36314 | 8.829e-4 |
| -1,038.8 | 3.88 | 3.7137 | 0.37598 | 9.5117e-4 |
| -1,148.6 | 3.8 | 3.8139 | 0.38953 | 0.0010262 |
| -1,272.8 | 3.72 | 3.9186 | 0.40384 | 0.0011087 |
| -1,418.9 | 3.64 | 4.0282 | 0.41896 | 0.0011997 |
| -1,601.6 | 3.56 | 4.1431 | 0.43498 | 0.0013002 |
| -1,858.4 | 3.48 | 4.2634 | 0.45195 | 0.0014115 |
| -2,342 | 3.4 | 4.3898 | 0.46995 | 0.001535 |
Interpreting this example
The signed target station is upstream. Chow used a coarser, rounded station table, so the 20-step calculation gives a slightly different reach length.
Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)
Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.
Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.
Worked examples
Open a case to load its inputs and interpretation.
- M2 drawdown to a drop structureA mild prismatic canal is controlled just upstream of a drop. Compare depths of 0.85 m at the control and 0.94 m upstream.
- M3 rise after a gateSupercritical flow enters a mild reach at 0.39 m. Calculate where it could reach 0.49 m if the modeled regime persists.
- S2 profile at a steep chuteA trapezoidal chute with a 2.3% bed grade and 0.025 roughness approaches its steep normal depth from above.
- H2 profile in a level canalA level rectangular canal is 3 m wide and carries 4.5 m³/s. Its 1.4 m control depth is traced toward 1.1 m.
- A3 reach on an adverse invertA 1.2 m flume carries 1.4 m³/s while the invert rises 0.15% downstream. Trace shallow flow from 0.28 to 0.38 m.
- Backwater at a low canal bankA downstream check raises the water to 1.69 m beside a bank 1.84 m above the invert. The required clearance is 0.25 m.