Channels
Backwater & GVF Direct-Step Calculator
Trace a 20-step Chow backwater or drawdown profile with signed stationing, slope and profile classification, and freeboard checks.
Inputs
Hydraulic readout
M1 · Upstream profile
Reach distance: 726.836 m, Normal depth: 1.02445 m, Critical depth: 0.654781 m, Min. freeboard: 0.3048 m
Input values
- Discharge Q
- 11.3267 m³/s
- Bottom width b
- 6.096 m
- Side slope z (H:1V)
- 2
- Bed slope S₀
- 0.0016
- Manning n
- 0.025
- Control depth y₁
- 1.524 m
- Target depth y₂
- 1.03632 m
- Bank depth
- 1.8288 m
- Minimum freeboard
- 0.1524 m
- Velocity-head factor α
- 1
- Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.
Calculation details
- Profile type
- M1
- Bed slope class
- Mild
- Direction
- Upstream
- Target station
- -726.836 m
- Required freeboard
- 0.1524 m
Direct-step station schedule
| Stationm | Depthm | Velocitym/s | Froude | Friction slope |
|---|---|---|---|---|
| 0 | 1.524 | 0.8128 | 0.24277 | 3.7295e-4 |
| -18.845 | 1.4996 | 0.83045 | 0.24972 | 3.9613e-4 |
| -37.999 | 1.4752 | 0.84872 | 0.25696 | 4.2111e-4 |
| -57.5 | 1.4508 | 0.86766 | 0.26453 | 4.4808e-4 |
| -77.394 | 1.4265 | 0.88731 | 0.27244 | 4.7722e-4 |
| -97.736 | 1.4021 | 0.90768 | 0.28071 | 5.0875e-4 |
| -118.59 | 1.3777 | 0.92884 | 0.28937 | 5.4291e-4 |
| -140.04 | 1.3533 | 0.95081 | 0.29844 | 5.7997e-4 |
| -162.19 | 1.3289 | 0.97365 | 0.30794 | 6.2022e-4 |
| -185.15 | 1.3045 | 0.99741 | 0.31791 | 6.6401e-4 |
| -209.09 | 1.2802 | 1.0221 | 0.32838 | 7.1171e-4 |
| -234.22 | 1.2558 | 1.0479 | 0.33938 | 7.6376e-4 |
| -260.81 | 1.2314 | 1.0747 | 0.35096 | 8.2064e-4 |
| -289.25 | 1.207 | 1.1027 | 0.36314 | 8.829e-4 |
| -320.07 | 1.1826 | 1.1319 | 0.37598 | 9.5117e-4 |
| -354.12 | 1.1582 | 1.1625 | 0.38953 | 0.0010262 |
| -392.7 | 1.1339 | 1.1944 | 0.40384 | 0.0011087 |
| -438.14 | 1.1095 | 1.2278 | 0.41896 | 0.0011997 |
| -495.1 | 1.0851 | 1.2628 | 0.43498 | 0.0013002 |
| -575.33 | 1.0607 | 1.2995 | 0.45195 | 0.0014115 |
| -726.84 | 1.0363 | 1.338 | 0.46995 | 0.001535 |
Calculation method
Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)
Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.
Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.
Worked examples
Open a case to load its inputs and interpretation.
- Chow M1 backwater behind a damAn idealized dam backs Chow’s 400 cfs trapezoidal channel up to 5 ft. Trace the profile toward 3.4 ft using α = 1.10.
- M2 drawdown to a drop structureA mild prismatic canal is controlled just upstream of a drop. Compare depths of 0.85 m at the control and 0.94 m upstream.
- M3 rise after a gateSupercritical flow enters a mild reach at 0.39 m. Calculate where it could reach 0.49 m if the modeled regime persists.
- S2 profile at a steep chuteA trapezoidal chute with a 2.3% bed grade and 0.025 roughness approaches its steep normal depth from above.
- H2 profile in a level canalA level rectangular canal is 3 m wide and carries 4.5 m³/s. Its 1.4 m control depth is traced toward 1.1 m.
- A3 reach on an adverse invertA 1.2 m flume carries 1.4 m³/s while the invert rises 0.15% downstream. Trace shallow flow from 0.28 to 0.38 m.
- Backwater at a low canal bankA downstream check raises the water to 1.69 m beside a bank 1.84 m above the invert. The required clearance is 0.25 m.