Worked example
S2 profile at a steep chute
A trapezoidal chute with a 2.3% bed grade and 0.025 roughness approaches its steep normal depth from above.
Inputs
Hydraulic readout
S2 · Upstream profile
Reach distance: 1.39406 m, Normal depth: 0.479288 m, Critical depth: 0.654781 m, Min. freeboard: 1.2188 m
Input values
- Discharge Q
- 11.3267 m³/s
- Bottom width b
- 6.096 m
- Side slope z (H:1V)
- 2
- Bed slope S₀
- 0.023
- Manning n
- 0.025
- Control depth y₁
- 0.57 m
- Target depth y₂
- 0.61 m
- Bank depth
- 1.8288 m
- Minimum freeboard
- 0.1524 m
- Velocity-head factor α
- 1
- Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.
Calculation details
- Profile type
- S2
- Bed slope class
- Steep
- Direction
- Upstream
- Target station
- -1.39406 m
- Required freeboard
- 0.1524 m
Direct-step station schedule
| Stationm | Depthm | Velocitym/s | Froude | Friction slope |
|---|---|---|---|---|
| 0 | 0.57 | 2.7462 | 1.2497 | 0.012644 |
| -0.10601 | 0.572 | 2.7351 | 1.2427 | 0.012491 |
| -0.20725 | 0.574 | 2.724 | 1.2358 | 0.012341 |
| -0.3039 | 0.576 | 2.7131 | 1.2289 | 0.012193 |
| -0.39616 | 0.578 | 2.7022 | 1.2221 | 0.012047 |
| -0.4842 | 0.58 | 2.6914 | 1.2154 | 0.011904 |
| -0.5682 | 0.582 | 2.6807 | 1.2087 | 0.011763 |
| -0.64832 | 0.584 | 2.67 | 1.2021 | 0.011623 |
| -0.72469 | 0.586 | 2.6595 | 1.1955 | 0.011486 |
| -0.79747 | 0.588 | 2.6489 | 1.189 | 0.011351 |
| -0.86678 | 0.59 | 2.6385 | 1.1825 | 0.011218 |
| -0.93275 | 0.592 | 2.6282 | 1.1761 | 0.011087 |
| -0.99551 | 0.594 | 2.6179 | 1.1698 | 0.010958 |
| -1.0552 | 0.596 | 2.6077 | 1.1635 | 0.010831 |
| -1.1118 | 0.598 | 2.5975 | 1.1572 | 0.010706 |
| -1.1655 | 0.6 | 2.5874 | 1.1511 | 0.010582 |
| -1.2165 | 0.602 | 2.5774 | 1.1449 | 0.010461 |
| -1.2647 | 0.604 | 2.5675 | 1.1388 | 0.010341 |
| -1.3104 | 0.606 | 2.5576 | 1.1328 | 0.010223 |
| -1.3534 | 0.608 | 2.5478 | 1.1268 | 0.010106 |
| -1.3941 | 0.61 | 2.5381 | 1.1209 | 0.0099915 |
Interpreting this example
The S2 classification uses depths between normal and critical. Test a separate case before connecting across either reference.
Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)
Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.
Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.
Worked examples
Open a case to load its inputs and interpretation.
- Chow M1 backwater behind a damAn idealized dam backs Chow’s 400 cfs trapezoidal channel up to 5 ft. Trace the profile toward 3.4 ft using α = 1.10.
- M2 drawdown to a drop structureA mild prismatic canal is controlled just upstream of a drop. Compare depths of 0.85 m at the control and 0.94 m upstream.
- M3 rise after a gateSupercritical flow enters a mild reach at 0.39 m. Calculate where it could reach 0.49 m if the modeled regime persists.
- H2 profile in a level canalA level rectangular canal is 3 m wide and carries 4.5 m³/s. Its 1.4 m control depth is traced toward 1.1 m.
- A3 reach on an adverse invertA 1.2 m flume carries 1.4 m³/s while the invert rises 0.15% downstream. Trace shallow flow from 0.28 to 0.38 m.
- Backwater at a low canal bankA downstream check raises the water to 1.69 m beside a bank 1.84 m above the invert. The required clearance is 0.25 m.