Worked example

S2 profile at a steep chute

A trapezoidal chute with a 2.3% bed grade and 0.025 roughness approaches its steep normal depth from above.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Use a positive slope for falling bed, zero for level or a negative value for adverse slope.
Profile controls
m
m
m
m
Use 1 for uniform section velocity.

Hydraulic readout

S2 · Upstream profile

Reach distance: 1.39406 m, Normal depth: 0.479288 m, Critical depth: 0.654781 m, Min. freeboard: 1.2188 m

Gradually varied water-surface profileThe direct-step stations are plotted with the channel bed, critical depth and normal depth where defined. The second chart compares depth and available freeboard.REACH DISTANCE1.3941 mNORMAL DEPTH0.47929 mCRITICAL DEPTH0.65478 mMIN. FREEBOARD1.2188 mWater surface · downstream →WaterNormal yₙCrit. y꜀Channel depth & freeboardDepthLimitBankAvailable freeboard1.2188 m / 0.1524 m
  • Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.

Calculation details

Profile type
S2
Bed slope class
Steep
Direction
Upstream
Target station
-1.39406 m
Required freeboard
0.1524 m

Direct-step station schedule

StationmDepthmVelocitym/sFroudeFriction slope
00.572.74621.24970.012644
-0.106010.5722.73511.24270.012491
-0.207250.5742.7241.23580.012341
-0.30390.5762.71311.22890.012193
-0.396160.5782.70221.22210.012047
-0.48420.582.69141.21540.011904
-0.56820.5822.68071.20870.011763
-0.648320.5842.671.20210.011623
-0.724690.5862.65951.19550.011486
-0.797470.5882.64891.1890.011351
-0.866780.592.63851.18250.011218
-0.932750.5922.62821.17610.011087
-0.995510.5942.61791.16980.010958
-1.05520.5962.60771.16350.010831
-1.11180.5982.59751.15720.010706
-1.16550.62.58741.15110.010582
-1.21650.6022.57741.14490.010461
-1.26470.6042.56751.13880.010341
-1.31040.6062.55761.13280.010223
-1.35340.6082.54781.12680.010106
-1.39410.612.53811.12090.0099915

Interpreting this example

The S2 classification uses depths between normal and critical. Test a separate case before connecting across either reference.

Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)

Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.

Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet