Worked example
M3 rise after a gate
Supercritical flow enters a mild reach at 0.39 m. Calculate where it could reach 0.49 m if the modeled regime persists.
Inputs
Hydraulic readout
M3 · Downstream profile
Reach distance: 8.66454 m, Normal depth: 1.02445 m, Critical depth: 0.654781 m, Min. freeboard: 1.3388 m
Input values
- Discharge Q
- 11.3267 m³/s
- Bottom width b
- 6.096 m
- Side slope z (H:1V)
- 2
- Bed slope S₀
- 0.0016
- Manning n
- 0.025
- Control depth y₁
- 0.39 m
- Target depth y₂
- 0.49 m
- Bank depth
- 1.8288 m
- Minimum freeboard
- 0.1524 m
- Velocity-head factor α
- 1
- Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.
Calculation details
- Profile type
- M3
- Bed slope class
- Mild
- Direction
- Downstream
- Target station
- 8.66454 m
- Required freeboard
- 0.1524 m
Direct-step station schedule
| Stationm | Depthm | Velocitym/s | Froude | Friction slope |
|---|---|---|---|---|
| 0 | 0.39 | 4.2238 | 2.279 | 0.046614 |
| 0.46468 | 0.395 | 4.1643 | 2.2339 | 0.04463 |
| 0.92712 | 0.4 | 4.1063 | 2.1902 | 0.042752 |
| 1.3872 | 0.405 | 4.0497 | 2.1479 | 0.040975 |
| 1.8446 | 0.41 | 3.9945 | 2.1069 | 0.039291 |
| 2.2994 | 0.415 | 3.9407 | 2.0671 | 0.037695 |
| 2.7512 | 0.42 | 3.8882 | 2.0285 | 0.036181 |
| 3.1999 | 0.425 | 3.8369 | 1.9911 | 0.034745 |
| 3.6454 | 0.43 | 3.7868 | 1.9548 | 0.03338 |
| 4.0874 | 0.435 | 3.7379 | 1.9195 | 0.032084 |
| 4.5258 | 0.44 | 3.6902 | 1.8852 | 0.030851 |
| 4.9604 | 0.445 | 3.6435 | 1.8519 | 0.029679 |
| 5.3909 | 0.45 | 3.5978 | 1.8195 | 0.028563 |
| 5.8172 | 0.455 | 3.5532 | 1.788 | 0.0275 |
| 6.239 | 0.46 | 3.5096 | 1.7574 | 0.026487 |
| 6.6562 | 0.465 | 3.4669 | 1.7276 | 0.025522 |
| 7.0685 | 0.47 | 3.4252 | 1.6986 | 0.024601 |
| 7.4757 | 0.475 | 3.3843 | 1.6704 | 0.023722 |
| 7.8776 | 0.48 | 3.3443 | 1.6429 | 0.022883 |
| 8.274 | 0.485 | 3.3051 | 1.6162 | 0.022081 |
| 8.6645 | 0.49 | 3.2668 | 1.5901 | 0.021316 |
Interpreting this example
The reach lies below critical depth. Use a separate momentum calculation if tailwater causes a hydraulic jump.
Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)
Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.
Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.
Worked examples
Open a case to load its inputs and interpretation.
- Chow M1 backwater behind a damAn idealized dam backs Chow’s 400 cfs trapezoidal channel up to 5 ft. Trace the profile toward 3.4 ft using α = 1.10.
- M2 drawdown to a drop structureA mild prismatic canal is controlled just upstream of a drop. Compare depths of 0.85 m at the control and 0.94 m upstream.
- S2 profile at a steep chuteA trapezoidal chute with a 2.3% bed grade and 0.025 roughness approaches its steep normal depth from above.
- H2 profile in a level canalA level rectangular canal is 3 m wide and carries 4.5 m³/s. Its 1.4 m control depth is traced toward 1.1 m.
- A3 reach on an adverse invertA 1.2 m flume carries 1.4 m³/s while the invert rises 0.15% downstream. Trace shallow flow from 0.28 to 0.38 m.
- Backwater at a low canal bankA downstream check raises the water to 1.69 m beside a bank 1.84 m above the invert. The required clearance is 0.25 m.