Worked example
A3 reach on an adverse invert
A 1.2 m flume carries 1.4 m³/s while the invert rises 0.15% downstream. Trace shallow flow from 0.28 to 0.38 m.
Inputs
Hydraulic readout
A3 · Downstream profile
Reach distance: 9.50029 m, Critical depth: 0.517755 m, Min. freeboard: 0.37 m
Input values
- Discharge Q
- 1.4 m³/s
- Bottom width b
- 1.2 m
- Side slope z (H:1V)
- 0
- Bed slope S₀
- -0.0015
- Manning n
- 0.017
- Control depth y₁
- 0.28 m
- Target depth y₂
- 0.38 m
- Bank depth
- 0.75 m
- Minimum freeboard
- 0.14 m
- Velocity-head factor α
- 1
- Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.
Calculation details
- Profile type
- A3
- Bed slope class
- Adverse
- Direction
- Downstream
- Target station
- 9.50029 m
- Required freeboard
- 0.14 m
Direct-step station schedule
| Stationm | Depthm | Velocitym/s | Froude | Friction slope |
|---|---|---|---|---|
| 0 | 0.28 | 4.1667 | 2.5145 | 0.045643 |
| 0.56059 | 0.285 | 4.0936 | 2.4486 | 0.043354 |
| 1.1134 | 0.29 | 4.023 | 2.3856 | 0.041221 |
| 1.6583 | 0.295 | 3.9548 | 2.3252 | 0.03923 |
| 2.195 | 0.3 | 3.8889 | 2.2673 | 0.037369 |
| 2.7233 | 0.305 | 3.8251 | 2.2118 | 0.035628 |
| 3.243 | 0.31 | 3.7634 | 2.1585 | 0.033997 |
| 3.7538 | 0.315 | 3.7037 | 2.1073 | 0.032468 |
| 4.2556 | 0.32 | 3.6458 | 2.0581 | 0.031032 |
| 4.7482 | 0.325 | 3.5897 | 2.0108 | 0.029683 |
| 5.2313 | 0.33 | 3.5354 | 1.9652 | 0.028413 |
| 5.7048 | 0.335 | 3.4826 | 1.9214 | 0.027218 |
| 6.1685 | 0.34 | 3.4314 | 1.8792 | 0.026091 |
| 6.6221 | 0.345 | 3.3816 | 1.8385 | 0.025029 |
| 7.0655 | 0.35 | 3.3333 | 1.7992 | 0.024025 |
| 7.4984 | 0.355 | 3.2864 | 1.7613 | 0.023076 |
| 7.9207 | 0.36 | 3.2407 | 1.7248 | 0.022179 |
| 8.3323 | 0.365 | 3.1963 | 1.6895 | 0.02133 |
| 8.7328 | 0.37 | 3.1532 | 1.6553 | 0.020525 |
| 9.1222 | 0.375 | 3.1111 | 1.6223 | 0.019762 |
| 9.5003 | 0.38 | 3.0702 | 1.5904 | 0.019038 |
Interpreting this example
Both depths are below critical, which gives A3. The adverse slope and friction act together in the longitudinal energy balance.
Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)
Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.
Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.
Worked examples
Open a case to load its inputs and interpretation.
- Chow M1 backwater behind a damAn idealized dam backs Chow’s 400 cfs trapezoidal channel up to 5 ft. Trace the profile toward 3.4 ft using α = 1.10.
- M2 drawdown to a drop structureA mild prismatic canal is controlled just upstream of a drop. Compare depths of 0.85 m at the control and 0.94 m upstream.
- M3 rise after a gateSupercritical flow enters a mild reach at 0.39 m. Calculate where it could reach 0.49 m if the modeled regime persists.
- S2 profile at a steep chuteA trapezoidal chute with a 2.3% bed grade and 0.025 roughness approaches its steep normal depth from above.
- H2 profile in a level canalA level rectangular canal is 3 m wide and carries 4.5 m³/s. Its 1.4 m control depth is traced toward 1.1 m.
- Backwater at a low canal bankA downstream check raises the water to 1.69 m beside a bank 1.84 m above the invert. The required clearance is 0.25 m.