Worked example

Energy loss at an outlet apron

A 5.5 m outlet passes 28 m³/s at y₁ = 0.53 m before the rectangular hydraulic jump.

Results ↓

Inputs

Approach section
m
m
Approach flow
m³/s

Hydraulic readout

Oscillating hydraulic jump

Sequent depth: 2.9041 m, Head loss: 2.17345 m, Power loss: 596.799 kW, Basin length: 17.2581 m

Hydraulic jump longitudinal sectionThe approach depth steps into the conjugate tailwater. The station bar indicates basin or natural jump length when available.SEQUENT DEPTH2.9041 mHEAD LOSS2.1734 mPOWER LOSS596.8 kWBASIN LENGTH17.258 mJump and rollerDepth y₁Depth y₂Length LⱼSpecific energy before / afterApproachRetainedLoss ΔEEnergy retained58.476%
  • Energy efficiency is the fraction of upstream specific energy retained. Lengths are rounded EM 25 chart estimates.
  • Check wave suppression and a tailwater depth of roughly 1.05–1.10 times y₂.

Calculation details

Upstream Froude
4.21329
Jump class
Oscillating
Discharge
28 m³/s
Unit discharge
5.09091 m²/s
Upstream velocity
9.60549 m/s
Downstream velocity
1.75301 m/s
Jump height
2.3741 m
Energy retained
58.4763%
Natural jump length
17.2581 m
USBR basin screen
Type IV

Interpreting this example

Dissipated power scales with both flow and head loss. Switch to US units to read the same power as mechanical horsepower.

y₂/y₁ = [√(1 + 8 Fr₁²) − 1]/2 · ΔE = (y₂ − y₁)³/(4 y₁ y₂)

The Bélanger relation balances momentum across a jump in a horizontal rectangular channel. The basin screen uses EM 25 Figure 12 and selects Type III at Fr₁ ≥ 4.5 only within the 50 ft/s and 200 cfs/ft screens.

Verify tailwater, waves, appurtenances and cavitation at the full operating range. Chart lengths are preliminary geometric estimates.