Worked example

Type III canal drop

A rectangular canal drops onto a level apron with 0.32 m of incoming depth and a 10.8 m/s jet.

Results ↓

Inputs

Approach section
m
m
Approach flow
m/s

Hydraulic readout

Steady hydraulic jump

Sequent depth: 2.60365 m, Head loss: 3.57351 m, Power loss: 351.226 kW, Basin length: 6.42887 m

Hydraulic jump longitudinal sectionThe approach depth steps into the conjugate tailwater. The station bar indicates basin or natural jump length when available.SEQUENT DEPTH2.6036 mHEAD LOSS3.5735 mPOWER LOSS351.23 kWBASIN LENGTH6.4289 mJump and rollerDepth y₁Depth y₂Length LⱼSpecific energy before / afterApproachRetainedLoss ΔEEnergy retained42.979%
  • Energy efficiency is the fraction of upstream specific energy retained. Lengths are rounded EM 25 chart estimates.

Calculation details

Upstream Froude
6.09661
Jump class
Steady
Discharge
10.0224 m³/s
Unit discharge
3.456 m²/s
Upstream velocity
10.8 m/s
Downstream velocity
1.32737 m/s
Jump height
2.28365 m
Energy retained
42.9789%
Natural jump length
15.8839 m
USBR basin screen
Type III

Interpreting this example

Entrance velocity falls within the preliminary Type III range. Compare the shorter appurtenant basin with the natural roller length.

y₂/y₁ = [√(1 + 8 Fr₁²) − 1]/2 · ΔE = (y₂ − y₁)³/(4 y₁ y₂)

The Bélanger relation balances momentum across a jump in a horizontal rectangular channel. The basin screen uses EM 25 Figure 12 and selects Type III at Fr₁ ≥ 4.5 only within the 50 ft/s and 200 cfs/ft screens.

Verify tailwater, waves, appurtenances and cavitation at the full operating range. Chart lengths are preliminary geometric estimates.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet