Worked example

USBR Type II spillway toe

EM 25’s high-dam example delivers roughly 480 cfs per foot with a 4.44 ft incoming depth. Use a 1 ft reference width.

Results ↓

Inputs

Approach section
ft
ft
Approach flow
cfs/ft

Hydraulic readout

Strong hydraulic jump

Sequent depth: 54.6186 ft, Head loss: 130.248 ft, Power loss: 7,096.27 HP, Basin length: 233.772 ft

Hydraulic jump longitudinal sectionThe approach depth steps into the conjugate tailwater. The station bar indicates basin or natural jump length when available.SEQUENT DEPTH54.619 ftHEAD LOSS130.25 ftPOWER LOSS7,096.3 HPBASIN LENGTH233.77 ftJump and rollerDepth y₁Depth y₂Length LⱼSpecific energy before / afterApproachRetainedLoss ΔEEnergy retained29.999%
  • Energy efficiency is the fraction of upstream specific energy retained. Lengths are rounded EM 25 chart estimates.

Calculation details

Upstream Froude
9.04511
Jump class
Strong
Discharge
480 cfs
Unit discharge
480 cfs/ft
Upstream velocity
108.108 ft/s
Downstream velocity
8.78821 ft/s
Jump height
50.1786 ft
Energy retained
29.9993%
Natural jump length
334.217 ft
USBR basin screen
Type II

Interpreting this example

The published chart reads about 54.6 ft of conjugate depth and 234 ft of Type II basin length. Final tailwater includes a project-specific margin.

y₂/y₁ = [√(1 + 8 Fr₁²) − 1]/2 · ΔE = (y₂ − y₁)³/(4 y₁ y₂)

The Bélanger relation balances momentum across a jump in a horizontal rectangular channel. The basin screen uses EM 25 Figure 12 and selects Type III at Fr₁ ≥ 4.5 only within the 50 ft/s and 200 cfs/ft screens.

Verify tailwater, waves, appurtenances and cavitation at the full operating range. Chart lengths are preliminary geometric estimates.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet