Cooling time 13.02 s
Heat load 2.24 kW
Coolant flow 10.73 L/min
Channel Re 17,736
Slab-center cooling and water circuit Live schematic
SLAB CENTER WATER CHANNELS 13.02 s Ø 8 mm Melt 235 °C Eject 94 °C
Turbulent channel flow
Re 0 4,000 target 6,000+
Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Refrigeration equivalent 0.64 TR Resin enthalpy removed 260.85 kJ/kg Heat removed per shot 62.6 kJ Flow per parallel circuit 5.37 L/min Channel mean velocity 1.78 m/s Cycle time minus cooling 14.98 s Re margin above 4,000 13,736
Working through the example
Size the heat removal from the full shot. Split total flow across both circuits for the Reynolds check.
t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.
Methodology and sources
t_c = s²/(π²α) × ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]
Inputs Maximum wall thickness 3 mm Resin thermal diffusivity 0.12 mm²/s Melt temperature 235 °C Ejection temperature 94 °C Mold wall temperature 52 °C Part and runner mass per shot 0.24 kg Total cycle time 28 s Resin specific heat 1.85 kJ/(kg·K) Latent heat released 0 kJ/kg Channel inner diameter 8 mm Equal-flow parallel circuits 2 Allowable coolant temperature rise 3 °C Coolant specific heat 4.18 kJ/(kg·K) Coolant density 0.997 kg/L Coolant dynamic viscosity 0.8 mPa·s
Results Cooling time 13.02 s Heat load 2.24 kW Coolant flow 10.73 L/min Channel Re 17,736 Refrigeration equivalent 0.64 TR Resin enthalpy removed 260.85 kJ/kg Heat removed per shot 62.6 kJ Flow per parallel circuit 5.37 L/min Channel mean velocity 1.78 m/s Cycle time minus cooling 14.98 s Re margin above 4,000 13,736
Turbulent channel flow. Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
SLAB CENTER WATER CHANNELS 13.02 s Ø 8 mm Melt 235 °C Eject 94 °C
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.