Ejection target close to the mold wall

The center must reach 79°C while the mold wall is held at 75°C.

Edit inputs ↓

Inputs

Part and mold
mm
mm²/s
°C
°C
°C
Heat per cycle
kg
s
kJ/(kg·K)
kJ/kg
Use zero for an amorphous resin or include crystallization heat if known.
Coolant circuit
mm
°C
kJ/(kg·K)
kg/L
mPa·s
Review calculations ↑
Cooling time
13.06s
Heat load
1.69kW
Coolant flow
8.1L/min
Channel Re
26,782

Slab-center cooling and water circuit

Live schematic
SLAB CENTERWATER CHANNEL13.06 sØ 8 mmMelt 225 °CEject 79 °C

Turbulent channel flow

Re 04,000 target6,000+

Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.

Calculation details
Refrigeration equivalent0.48 TR
Resin enthalpy removed270.1 kJ/kg
Heat removed per shot54.02 kJ
Flow per parallel circuit8.1 L/min
Channel mean velocity2.69 m/s
Cycle time minus cooling18.94 s
Re margin above 4,00022,782

Working through the example

The small ejection-to-wall temperature difference lengthens the cooling estimate. The logarithm stays finite while the temperature order holds.

t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.

The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.

Methodology and sources