Cooling time 6.85 s
Heat load 0.76 kW
Coolant flow 2.72 L/min
Channel Re 2,448
Slab-center cooling and water circuit Live schematic
SLAB CENTER WATER CHANNELS 6.85 s Ø 8 mm Melt 230 °C Eject 90 °C
Transitional channel flow
Re 0 4,000 target 6,000+
Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Refrigeration equivalent 0.21 TR Resin enthalpy removed 252 kJ/kg Heat removed per shot 22.68 kJ Flow per parallel circuit 0.91 L/min Channel mean velocity 0.3 m/s Cycle time minus cooling 23.15 s Re margin above 4,000 -1,552
Working through the example
The per-branch Reynolds number falls between 2,300 and 4,000. Check each circuit individually during commissioning.
t_c = [s²/(π²α)] ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]. Heat (kW) = m_shot[cₚ(Tₘ−Tₑ) + ΔH_f]/t_cycle.
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.
Methodology and sources
t_c = s²/(π²α) × ln[(4/π)(Tₘ−T𝓌)/(Tₑ−T𝓌)]
Inputs Maximum wall thickness 2.2 mm Resin thermal diffusivity 0.115 mm²/s Melt temperature 230 °C Ejection temperature 90 °C Mold wall temperature 42 °C Part and runner mass per shot 0.09 kg Total cycle time 30 s Resin specific heat 1.8 kJ/(kg·K) Latent heat released 0 kJ/kg Channel inner diameter 8 mm Equal-flow parallel circuits 3 Allowable coolant temperature rise 4 °C Coolant specific heat 4.18 kJ/(kg·K) Coolant density 0.997 kg/L Coolant dynamic viscosity 0.98 mPa·s
Results Cooling time 6.85 s Heat load 0.76 kW Coolant flow 2.72 L/min Channel Re 2,448 Refrigeration equivalent 0.21 TR Resin enthalpy removed 252 kJ/kg Heat removed per shot 22.68 kJ Flow per parallel circuit 0.91 L/min Channel mean velocity 0.3 m/s Cycle time minus cooling 23.15 s Re margin above 4,000 -1,552
Transitional channel flow. Turbulence screen uses Re ≥ 4,000 per equal-flow branch. Compare the slab cooling estimate with the total cycle separately.
SLAB CENTER WATER CHANNELS 6.85 s Ø 8 mm Melt 230 °C Eject 90 °C
The slab starts at uniform melt temperature, with constant diffusivity and two surfaces held at the entered wall temperature. The first Fourier term estimates when the center reaches the ejection temperature. The plot caps that approximation at melt temperature near time zero. Water flow is from the steady heat balance. Divide it across equal branches and calculate Re = ρuD/μ, screened at 4,000. Chiller selection also depends on site loads, distribution loss and equipment margin.