105 µm finished copper with a 9 mm trace

A fabricator specifies 105 µm finished copper for a power-distribution trace on a controller PCB.

Design inputs

Trace & thermal limits

Enter 0 to use the calculated width.

Copper foil
View live readout ↑

Live readout

Edit inputs
Min. width
2.859 mm
Hot resistance
1.726 mΩ
Voltage drop
29.34 mV
Trace rise
3.779 °C
Trace cross-section Trace cross-section External layer Routing widthSubstrateReference planeWidth9 mmCopper foil105 µmTrace rise3.78 °C
The board section highlights which layer carries current. Its dimensions come from the entered foil and installed trace width.
Trace has rise headroom

IPC-2221 curve fit. Nearby planes, board construction and airflow affect real temperature rise.

Trace rise / goal3.779 °C / 25 °C

Result breakdown
Minimum trace width2.85905 mm
Minimum trace width in mils112.561 mil
Trace width used in readout9 mm
Minimum cross-sectional area0.3002 mm²
Cross-sectional area used0.945 mm²
Finished copper thickness105 µm
Estimated temperature rise3.77866 °C
Estimated copper temperature48.7787 °C
Temperature-corrected resistance1.72607 mΩ
Voltage drop29.3432 mV
Trace dissipation0.498834 W
Temperature-rise headroom21.2213 °C

Worked calculation

Width = 0.3002 mm² / 0.105 mm = 2.85905 mm at 25 °C rise

Try the imperial toggle with custom foil active. The estimated resistance and dissipation should stay the same.

IPC-2221 fit

I = k · ΔT^0.44 · A^0.725 | A in mil²

Use k = 0.048 for external copper and 0.024 for internal copper. Divide the solved area by finished foil thickness for minimum width. Reversing the fit with an installed width estimates actual rise. One ounce per square foot is approximated as 35 µm.

Hot resistance

R = ρ20 · [1 + 0.00393 · (Tcu − 20 °C)] · ℓ / A

Tcu is ambient plus modeled rise and ρ20 is 1.724 × 10⁻⁸ Ω·m. Voltage drop is I·R and dissipation is I²·R. Use RMS current for heating and the current of interest for the voltage-drop estimate.

IPC-2152 context

Check stackup, nearby copper and heat spreading

This screening fit uses IPC-2221 chart constants. IPC-2152 gives separate current-carrying guidance including the effects of board geometry and nearby planes. Check adjacent traces, via bottlenecks, finished copper tolerance and enclosure conditions.