8 A internal trace on 2 oz copper

Check a 7.5 mm internal trace in a multilayer power board with 2 oz inner copper.

Design inputs

Trace & thermal limits

Enter 0 to use the calculated width.

Copper foil
View live readout ↑

Live readout

Edit inputs
Min. width
4.815 mm
Hot resistance
2.502 mΩ
Voltage drop
20.02 mV
Trace rise
8.672 °C
Trace cross-section Trace cross-section Internal layer Routing widthSubstrateReference planeWidth7.5 mmCopper foil70 µmTrace rise8.67 °C
The board section highlights which layer carries current. Its dimensions come from the entered foil and installed trace width.
Trace has rise headroom

IPC-2221 curve fit. Nearby planes, board construction and airflow affect real temperature rise.

Trace rise / goal8.672 °C / 18 °C

Result breakdown
Minimum trace width4.81484 mm
Minimum trace width in mils189.561 mil
Trace width used in readout7.5 mm
Minimum cross-sectional area0.337039 mm²
Cross-sectional area used0.525 mm²
Finished copper thickness70 µm
Estimated temperature rise8.67198 °C
Estimated copper temperature50.672 °C
Temperature-corrected resistance2.50216 mΩ
Voltage drop20.0173 mV
Trace dissipation0.160138 W
Temperature-rise headroom9.32802 °C

Worked calculation

Width = 0.337039 mm² / 0.07 mm = 4.81484 mm at 18 °C rise

Switch to an external layer to see the impact of the IPC-2221 fit. Compare the estimated rise with your stackup data.

IPC-2221 fit

I = k · ΔT^0.44 · A^0.725 | A in mil²

Use k = 0.048 for external copper and 0.024 for internal copper. Divide the solved area by finished foil thickness for minimum width. Reversing the fit with an installed width estimates actual rise. One ounce per square foot is approximated as 35 µm.

Hot resistance

R = ρ20 · [1 + 0.00393 · (Tcu − 20 °C)] · ℓ / A

Tcu is ambient plus modeled rise and ρ20 is 1.724 × 10⁻⁸ Ω·m. Voltage drop is I·R and dissipation is I²·R. Use RMS current for heating and the current of interest for the voltage-drop estimate.

IPC-2152 context

Check stackup, nearby copper and heat spreading

This screening fit uses IPC-2221 chart constants. IPC-2152 gives separate current-carrying guidance including the effects of board geometry and nearby planes. Check adjacent traces, via bottlenecks, finished copper tolerance and enclosure conditions.