The board section highlights which layer carries current. Its dimensions come from the entered foil and installed trace width.
Trace has rise headroom
IPC-2221 curve fit. Nearby planes, board construction and airflow affect real temperature rise.
Trace rise / goal3.34 °C / 20 °C
Result breakdown
Minimum trace width
2.02484 mm
Minimum trace width in mils
79.7182 mil
Trace width used in readout
6 mm
Minimum cross-sectional area
0.212608 mm²
Cross-sectional area used
0.63 mm²
Finished copper thickness
105 µm
Estimated temperature rise
3.33963 °C
Estimated copper temperature
40.3396 °C
Temperature-corrected resistance
3.25077 mΩ
Voltage drop
39.0093 mV
Trace dissipation
0.468112 W
Temperature-rise headroom
16.6604 °C
Worked calculation
Width = 0.212608 mm² / 0.105 mm = 2.02484 mm at 20 °C rise
Halve trace length to isolate its effect on voltage drop and watts. The IPC width at a given modeled rise stays fixed.
IPC-2221 fit
I = k · ΔT^0.44 · A^0.725 | A in mil²
Use k = 0.048 for external copper and 0.024 for internal copper. Divide the solved area by finished foil thickness for minimum width. Reversing the fit with an installed width estimates actual rise. One ounce per square foot is approximated as 35 µm.
Hot resistance
R = ρ20 · [1 + 0.00393 · (Tcu − 20 °C)] · ℓ / A
Tcu is ambient plus modeled rise and ρ20 is 1.724 × 10⁻⁸ Ω·m. Voltage drop is I·R and dissipation is I²·R. Use RMS current for heating and the current of interest for the voltage-drop estimate.
IPC-2152 context
Check stackup, nearby copper and heat spreading
This screening fit uses IPC-2221 chart constants. IPC-2152 gives separate current-carrying guidance including the effects of board geometry and nearby planes. Check adjacent traces, via bottlenecks, finished copper tolerance and enclosure conditions.