The board section highlights which layer carries current. Its dimensions come from the entered foil and installed trace width.
Trace exceeds rise goal
IPC-2221 curve fit. Nearby planes, board construction and airflow affect real temperature rise.
Trace rise / goal14.26 °C / 12 °C
Result breakdown
Minimum trace width
3.22037 mm
Minimum trace width in mils
126.786 mil
Trace width used in readout
2.9 mm
Minimum cross-sectional area
0.225426 mm²
Cross-sectional area used
0.203 mm²
Finished copper thickness
70 µm
Estimated temperature rise
14.2615 °C
Estimated copper temperature
44.2615 °C
Temperature-corrected resistance
4.18606 mΩ
Voltage drop
41.8606 mV
Trace dissipation
0.418606 W
Temperature-rise headroom
-2.26152 °C
Worked calculation
Width = 0.225426 mm² / 0.07 mm = 3.22037 mm at 12 °C rise
The selected width misses the rise goal. Read the modeled hotter resistance before comparing wider copper or another layer.
IPC-2221 fit
I = k · ΔT^0.44 · A^0.725 | A in mil²
Use k = 0.048 for external copper and 0.024 for internal copper. Divide the solved area by finished foil thickness for minimum width. Reversing the fit with an installed width estimates actual rise. One ounce per square foot is approximated as 35 µm.
Hot resistance
R = ρ20 · [1 + 0.00393 · (Tcu − 20 °C)] · ℓ / A
Tcu is ambient plus modeled rise and ρ20 is 1.724 × 10⁻⁸ Ω·m. Voltage drop is I·R and dissipation is I²·R. Use RMS current for heating and the current of interest for the voltage-drop estimate.
IPC-2152 context
Check stackup, nearby copper and heat spreading
This screening fit uses IPC-2221 chart constants. IPC-2152 gives separate current-carrying guidance including the effects of board geometry and nearby planes. Check adjacent traces, via bottlenecks, finished copper tolerance and enclosure conditions.