Ringing with a critical damping target

Compare an illustrative critical response against an undamped switching-node capture.

Design inputs

Scope measurements
RC selection

Sets the illustrative damped waveform and the optional resistor estimate.

View live readout ↑

Live readout

Edit inputs
Snubber R
6.992 Ω
Snubber C
513.5 pF
Resistor heat
0.1597 W
2× rating
0.3194 W
Switch-node ring-down Switch-node ring-down 48.8 ns span SWTime →Original f₀82 MHzLoaded f₁51 MHzTarget ζ1
The damped trace illustrates the target ζ. Bench ringing can differ as voltage-dependent capacitance and loop impedance change.
2× power target met

Verify pulse-energy rating and temperature derating on the resistor datasheet.

2× dissipation / resistor rating0.3194 W / 1 W

Result breakdown
Inferred parasitic capacitance138.787 pF
Inferred parasitic inductance27.1433 nH
Characteristic impedance13.9848 Ω
Recommended snubber resistor6.99241 Ω
Recommended snubber capacitor513.513 pF
Resistor dissipation estimate0.159723 W
Minimum resistor rating (2×)0.319446 W
Power-rating headroom0.680554 W

Worked calculation

Cpar = 220 pF / [(82 / 51)² − 1] = 138.787 pF

Set ζ back to 0.7 and compare the response shape and the resistor recommendation.

Two captures

Cpar = Ctest / [(f₀/f₁)² − 1] | Lpar = 1 / [(2πf₀)²·Cpar]

Measure the same ringing mode with and without a known parallel test capacitor. Aim for roughly half the original frequency. Nearly equal readings amplify measurement error. Using an installed resistor during the measurement shifts the result.

RC starting point

Z₀ = √(Lpar/Cpar) | Cs = multiplier · Cpar

Start with Rs = Z₀ and Cs = 3·Cpar. Z₀/(2ζ) uses the parallel-resistor approximation at the ringing frequency. The plotted target is illustrative. Component placement and the measured ring-down determine the final values.

Resistor load

Psnub ≈ Cs · Vstep² · fs

This assumes charge and discharge through the resistor each cycle. Compare twice the estimated power to the continuous rating and check repetitive pulse energy separately.