Low-voltage switching with a small test capacitor

Use a small test capacitor to characterize a fast low-voltage switch node.

Design inputs

Scope measurements
RC selection

Sets the illustrative damped waveform and the optional resistor estimate.

View live readout ↑

Live readout

Edit inputs
Snubber R
15.52 Ω
Snubber C
159.8 pF
Resistor heat
0.02301 W
2× rating
0.04603 W
Switch-node ring-down Switch-node ring-down 26 ns span SWTime →Original f₀154 MHzLoaded f₁92 MHzTarget ζ0.7
The damped trace illustrates the target ζ. Bench ringing can differ as voltage-dependent capacitance and loop impedance change.
2× power target met

Verify pulse-energy rating and temperature derating on the resistor datasheet.

2× dissipation / resistor rating0.04603 W / 0.25 W

Result breakdown
Inferred parasitic capacitance66.5932 pF
Inferred parasitic inductance16.0387 nH
Characteristic impedance15.5192 Ω
Recommended snubber resistor15.5192 Ω
Recommended snubber capacitor159.824 pF
Resistor dissipation estimate0.0230146 W
Minimum resistor rating (2×)0.0460292 W
Power-rating headroom0.203971 W

Worked calculation

Cpar = 120 pF / [(154 / 92)² − 1] = 66.5932 pF

Compare the damped trace and modeled heat as you adjust the damping ratio and capacitance multiplier.

Two captures

Cpar = Ctest / [(f₀/f₁)² − 1] | Lpar = 1 / [(2πf₀)²·Cpar]

Measure the same ringing mode with and without a known parallel test capacitor. Aim for roughly half the original frequency. Nearly equal readings amplify measurement error. Using an installed resistor during the measurement shifts the result.

RC starting point

Z₀ = √(Lpar/Cpar) | Cs = multiplier · Cpar

Start with Rs = Z₀ and Cs = 3·Cpar. Z₀/(2ζ) uses the parallel-resistor approximation at the ringing frequency. The plotted target is illustrative. Component placement and the measured ring-down determine the final values.

Resistor load

Psnub ≈ Cs · Vstep² · fs

This assumes charge and discharge through the resistor each cycle. Compare twice the estimated power to the continuous rating and check repetitive pulse energy separately.