PCB Trace Width & Temperature Rise Calculator

Apply the IPC-2221 curve fit to a high-current trace and estimate hot resistance, voltage drop and heat.

Design inputs

Trace & thermal limits

Enter 0 to use the calculated width.

Copper foil
View live readout ↑

Live readout

Edit inputs
Min. width
2.067 mm
Hot resistance
7.325 mΩ
Voltage drop
58.6 mV
Trace rise
15 °C
Trace cross-section Trace cross-section External layer Routing widthSubstrateReference planeWidth2.07 mmCopper foil70 µmTrace rise15 °C
The board section highlights which layer carries current. Its dimensions come from the entered foil and installed trace width.
At the IPC fit target

IPC-2221 curve fit. Nearby planes, board construction and airflow affect real temperature rise.

Trace rise / goal15 °C / 15 °C

Result breakdown
Minimum trace width2.06739 mm
Minimum trace width in mils81.3933 mil
Trace width used in readout2.06739 mm
Minimum cross-sectional area0.144717 mm²
Cross-sectional area used0.144717 mm²
Finished copper thickness70 µm
Estimated temperature rise15 °C
Estimated copper temperature50 °C
Temperature-corrected resistance7.32457 mΩ
Voltage drop58.5966 mV
Trace dissipation0.468773 W
Temperature-rise headroom0 °C

Formulas and assumptions

IPC-2221 fit

I = k · ΔT^0.44 · A^0.725 | A in mil²

Use k = 0.048 for external copper and 0.024 for internal copper. Divide the solved area by finished foil thickness for minimum width. Reversing the fit with an installed width estimates actual rise. One ounce per square foot is approximated as 35 µm.

Hot resistance

R = ρ20 · [1 + 0.00393 · (Tcu − 20 °C)] · ℓ / A

Tcu is ambient plus modeled rise and ρ20 is 1.724 × 10⁻⁸ Ω·m. Voltage drop is I·R and dissipation is I²·R. Use RMS current for heating and the current of interest for the voltage-drop estimate.

IPC-2152 context

Check stackup, nearby copper and heat spreading

This screening fit uses IPC-2221 chart constants. IPC-2152 gives separate current-carrying guidance including the effects of board geometry and nearby planes. Check adjacent traces, via bottlenecks, finished copper tolerance and enclosure conditions.