Pneumatic rack-and-pinion

Butterfly valve on spring fail-open

A butterfly valve is configured to open when its pneumatic supply fails.

Inputs

Valve torque basis
Actuator geometry
Breakaway
705in-lb
Seating
570in-lb
Min. piston
3.71in
Worst margin
120in-lb
Stroke torque margins available

Air and return strokes meet the factored torque points at the selected supply pressure.

Demand and actuator torque

Demand and actuator torqueTorque is plotted against stroke progress in each direction. Compare available output with each direction’s demand.06261,252in-lb0°STROKE90°AIRSPRINGCLOSE DEMANDOPEN DEMANDMIN. AIR809 in-lbMIN. RETURN570 in-lbWORST MARGIN120 in-lb
Torque is plotted against stroke progress in each direction. Compare available output with each direction’s demand.

All calculated values
Factored breakaway torque705 in-lb
Factored seating torque570 in-lb
Factored running torque450 in-lb
Applied pressure torque multiplier1 ×
Supply pressure100 psig
Gross air torque1,729.13 in-lb
Minimum equivalent piston bore3.713 in
Air stroke directionClosing
Return stroke directionOpening
Air stroke start output1,159.13 in-lb
Air stroke end output809.13 in-lb
Return stroke start output920 in-lb
Return stroke end output570 in-lb
Air start torque margin709.13 in-lb
Air end torque margin239.13 in-lb
Return start torque margin215 in-lb
Return end torque margin120 in-lb
Worst stroke margin120 in-lb
Stem margin at selected pressure1,440.87 in-lb

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Factor the breakaway demand705 in-lb
  2. Find the equivalent air-side bore3.713 in
  3. Check the worst stroke point120 in-lb

The spring start point now carries breakaway demand and the air stroke ends at seating. Direction changes which endpoint governs.

Model and limits

Enter OEM breakaway, running and seating torque at the reference differential. Demand uses a service multiplier and a provisional valve-type correction of the form b + (1 − b) ΔP/ΔPref. Base fractions b are 0.35 for floating ball, 0.55 for trunnion, 0.50 for butterfly and 0.65 for plug.

Set the reference differential to the service differential when using OEM torque data for that duty. The equivalent bore assumes two equal pistons and constant pitch radius. It sizes the air side only. Use vendor start, mid-stroke and end torque tables for both directions, minimum air available while stroking, stem limits at maximum supply, and the actual fail-safe spring set.

View equations and references

Worked examples