Pneumatic rack-and-pinion
Oversized actuator versus stem torque limit
A larger actuator was proposed for a valve with a limited maximum allowable stem torque.
Inputs
Results
Edit inputs- Breakaway
- 80.5N·m
- Seating
- 69.2N·m
- Min. piston
- 58.8mm
- Worst margin
- 301N·m
At least one actuator output exceeds the entered stem torque limit.
Demand and actuator torque
All calculated values
| Factored breakaway torque | 80.5 N·m |
|---|---|
| Factored seating torque | 69.2 N·m |
| Factored running torque | 43.78 N·m |
| Applied pressure torque multiplier | 1 × |
| Supply pressure | 6.89 bar g |
| Gross air torque | 381.5 N·m |
| Minimum equivalent piston bore | 58.798 mm |
| Air stroke direction | Opening |
| Return stroke direction | Closing |
| Air stroke start output | 381.5 N·m |
| Air stroke end output | 381.5 N·m |
| Return stroke start output | 381.5 N·m |
| Return stroke end output | 381.5 N·m |
| Air start torque margin | 301 N·m |
| Air end torque margin | 337.72 N·m |
| Return start torque margin | 337.72 N·m |
| Return end torque margin | 312.3 N·m |
| Worst stroke margin | 301 N·m |
| Stem margin at selected pressure | -141.5 N·m |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Factor the breakaway demand80.5 N·m
- Find the equivalent air-side bore58.798 mm
- Check the worst stroke point301 N·m
An actuator may deliver more than the stem can withstand even when it clears stroke demand. Review the maximum possible supply with the OEM.
Model and limits
Enter OEM breakaway, running and seating torque at the reference differential. Demand uses a service multiplier and a provisional valve-type correction of the form b + (1 − b) ΔP/ΔPref. Base fractions b are 0.35 for floating ball, 0.55 for trunnion, 0.50 for butterfly and 0.65 for plug.
Set the reference differential to the service differential when using OEM torque data for that duty. The equivalent bore assumes two equal pistons and constant pitch radius. It sizes the air side only. Use vendor start, mid-stroke and end torque tables for both directions, minimum air available while stroking, stem limits at maximum supply, and the actual fail-safe spring set.
View equations and references