Pneumatic rack-and-pinion

Plug valve with 60 psig available air

A plug valve uses a conservative service multiplier for breakaway and a low minimum instrument-air pressure.

Inputs

Valve torque basis
Actuator geometry
Breakaway
1,365in-lb
Seating
1,137.5in-lb
Min. piston
4.59in
Worst margin
-991.5in-lb
Stroke torque shortfall

At least one air or return torque point falls below demand. A larger piston alone cannot correct weak fail springs.

Demand and actuator torque

Demand and actuator torqueTorque is plotted against stroke progress in each direction. Compare available output with each direction’s demand.07371,474in-lb0°STROKE90°AIR BOTH WAYSOPEN DEMANDCLOSE DEMANDMIN. AIR373 in-lbMIN. RETURN373 in-lbWORST MARGIN-992 in-lb
Torque is plotted against stroke progress in each direction. Compare available output with each direction’s demand.

All calculated values
Factored breakaway torque1,365 in-lb
Factored seating torque1,137.5 in-lb
Factored running torque752.5 in-lb
Applied pressure torque multiplier1 ×
Supply pressure60 psig
Gross air torque373.49 in-lb
Minimum equivalent piston bore4.588 in
Air stroke directionOpening
Return stroke directionClosing
Air stroke start output373.49 in-lb
Air stroke end output373.49 in-lb
Return stroke start output373.49 in-lb
Return stroke end output373.49 in-lb
Air start torque margin-991.51 in-lb
Air end torque margin-379.01 in-lb
Return start torque margin-379.01 in-lb
Return end torque margin-764.01 in-lb
Worst stroke margin-991.51 in-lb
Stem margin at selected pressure2,226.51 in-lb

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Factor the breakaway demand1,365 in-lb
  2. Find the equivalent air-side bore4.588 in
  3. Check the worst stroke point-991.51 in-lb

The trial piston is too small for the factored demand. Use the required equivalent bore to guide a vendor torque-table search.

Model and limits

Enter OEM breakaway, running and seating torque at the reference differential. Demand uses a service multiplier and a provisional valve-type correction of the form b + (1 − b) ΔP/ΔPref. Base fractions b are 0.35 for floating ball, 0.55 for trunnion, 0.50 for butterfly and 0.65 for plug.

Set the reference differential to the service differential when using OEM torque data for that duty. The equivalent bore assumes two equal pistons and constant pitch radius. It sizes the air side only. Use vendor start, mid-stroke and end torque tables for both directions, minimum air available while stroking, stem limits at maximum supply, and the actual fail-safe spring set.

View equations and references