Pneumatic rack-and-pinion
Spring end stalls before seating
A candidate fail-closed actuator has a strong air stroke but modest spring-end torque.
Inputs
Results
Edit inputs- Breakaway
- 855in-lb
- Seating
- 735in-lb
- Min. piston
- 3.62in
- Worst margin
- -275in-lb
At least one air or return torque point falls below demand. A larger piston alone cannot correct weak fail springs.
Demand and actuator torque
All calculated values
| Factored breakaway torque | 855 in-lb |
|---|---|
| Factored seating torque | 735 in-lb |
| Factored running torque | 465 in-lb |
| Applied pressure torque multiplier | 1 × |
| Supply pressure | 100 psig |
| Gross air torque | 1,906.37 in-lb |
| Minimum equivalent piston bore | 3.618 in |
| Air stroke direction | Opening |
| Return stroke direction | Closing |
| Air stroke start output | 1,446.37 in-lb |
| Air stroke end output | 956.37 in-lb |
| Return stroke start output | 950 in-lb |
| Return stroke end output | 460 in-lb |
| Air start torque margin | 591.37 in-lb |
| Air end torque margin | 491.37 in-lb |
| Return start torque margin | 485 in-lb |
| Return end torque margin | -275 in-lb |
| Worst stroke margin | -275 in-lb |
| Stem margin at selected pressure | 1,153.63 in-lb |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Factor the breakaway demand855 in-lb
- Find the equivalent air-side bore3.618 in
- Check the worst stroke point-275 in-lb
The spring end must seat without air. More air pressure or piston area leaves that independent shortfall in place.
Model and limits
Enter OEM breakaway, running and seating torque at the reference differential. Demand uses a service multiplier and a provisional valve-type correction of the form b + (1 − b) ΔP/ΔPref. Base fractions b are 0.35 for floating ball, 0.55 for trunnion, 0.50 for butterfly and 0.65 for plug.
Set the reference differential to the service differential when using OEM torque data for that duty. The equivalent bore assumes two equal pistons and constant pitch radius. It sizes the air side only. Use vendor start, mid-stroke and end torque tables for both directions, minimum air available while stroking, stem limits at maximum supply, and the actual fail-safe spring set.
View equations and references